Your browser doesn't support javascript.
loading
Stability of Direct Oral Anticoagulants and Antiarrhythmic Drugs in Serum Collected in Standard (Nongel) Serum Tubes Versus Tubes Containing Gel Separators.
Hegstad, Solfrid; Fuskevåg, Ole-Martin; Amundsen, Siri; Gule, Marina; Spigset, Olav; Helland, Arne.
Afiliação
  • Hegstad S; Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway.
  • Fuskevåg OM; Department of Laboratory Medicine, University Hospital of North Norway, Tromsø, Norway; and.
  • Amundsen S; Department of Laboratory Medicine, University Hospital of North Norway, Tromsø, Norway; and.
  • Gule M; Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway.
  • Spigset O; Department of Clinical Pharmacology, St. Olav University Hospital, Trondheim, Norway.
  • Helland A; Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway.
Ther Drug Monit ; 44(2): 328-334, 2022 04 01.
Article em En | MEDLINE | ID: mdl-34310545
BACKGROUND: Separation gels are often used in collection tubes, but adsorption of drugs onto the gel may cause falsely low concentrations in therapeutic drug monitoring. In this study, the stability of apixaban, edoxaban, rivaroxaban, flecainide, amiodarone, and desethylamiodarone was assessed in tubes, with and without gel separators. METHODS: Drug-free blood was spiked and stored for up to 7 days in nongel tubes and gel tubes from 2 manufacturers (Vacuette and Vacutainer). The samples were analyzed in triplicates using ultra-high-pressure liquid chromatography-tandem mass spectrometry. RESULTS: At ambient temperature conditions, the serum concentrations of apixaban, edoxaban, and rivaroxaban in a tube with acrylic-based gel had already decreased at baseline, whereas it took 6 hours to observe the same result in a tube with olefin-based gel. At 4°C, the reduction in serum concentration was considerably slower. For flecainide, the gel tube concentrations were stable at ambient temperature for 3 days, but decreased after 7 days in acrylic-based gel tubes. Amiodarone and desethylamiodarone stored in gel tubes at 4°C showed decrease in concentrations after 24 hours and 6 hours, respectively. CONCLUSIONS: Acrylic-based gel tubes should not be used for any of the tested drugs. Although olefin-based gel tubes may be used for anticoagulants and flecainide, it is advisable to prefer nongel tubes as a general precaution.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coleta de Amostras Sanguíneas / Antiarrítmicos Limite: Humans Idioma: En Revista: Ther Drug Monit Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coleta de Amostras Sanguíneas / Antiarrítmicos Limite: Humans Idioma: En Revista: Ther Drug Monit Ano de publicação: 2022 Tipo de documento: Article