Your browser doesn't support javascript.
loading
Optimization of a saccharin molecularly imprinted solid-phase extraction procedure and evaluation by MIR hyperspectral imaging for analysis of diet tea by HPLC.
Dourado, Camila Santos; Domingues, Izabella Fernanda F; de Oliveira Magalhães, Laiz; Casarin, Fabiana; Ribeiro, Millene Lopes; Braga, Jez Willian Batista; Dias, Ana Cristi Basile.
Afiliação
  • Dourado CS; Institute of Chemistry, University of Brasilia - UnB, Brasilia, DF 70910-900, Brazil.
  • Domingues IFF; Institute of Chemistry, University of Brasilia - UnB, Brasilia, DF 70910-900, Brazil.
  • de Oliveira Magalhães L; Institute of Chemistry, University of Brasilia - UnB, Brasilia, DF 70910-900, Brazil.
  • Casarin F; Institute of Chemistry, University of Brasilia - UnB, Brasilia, DF 70910-900, Brazil.
  • Ribeiro ML; Institute of Chemistry, University of Brasilia - UnB, Brasilia, DF 70910-900, Brazil.
  • Braga JWB; Institute of Chemistry, University of Brasilia - UnB, Brasilia, DF 70910-900, Brazil. Electronic address: jez@unb.br.
  • Dias ACB; Institute of Chemistry, University of Brasilia - UnB, Brasilia, DF 70910-900, Brazil. Electronic address: acbdias@unb.br.
Food Chem ; 367: 130732, 2022 Jan 15.
Article em En | MEDLINE | ID: mdl-34384980
ABSTRACT
Saccharin was determined based on a new molecularly imprinted solid-phase extraction (MISPE) procedure. The polymer was synthesized with a hybrid monomer of metacrylic acid and 3-amino propril tetraethoxysilane and saccharin as template. After the synthesis, the saccharin removal from the MIP was verified by the UV analysis of the solutions used in the template removal procedure, as well as by the direct MIP analysis using FTIR hyperspectral image and chemometrics. The residual saccharin concentrations observed in the image analysis revealed a narrow concentration distribution consistent with a homogenous material. The MISPE was performed with homemade cartridges containing 200 mg of the MIP. The results obtained with standards and diet tea samples confirmed high affinity, adsorption capacity and selectivity of the MIP. The MISPE cartridge exhibited recoveries of 100 ± 3% in six extraction cycles. The diet tea analysis showed a significant reduction of the interferences, which can considerable simplifies the HPLC-UV analysis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Impressão Molecular Idioma: En Revista: Food Chem Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Impressão Molecular Idioma: En Revista: Food Chem Ano de publicação: 2022 Tipo de documento: Article