Your browser doesn't support javascript.
loading
Trueness and marginal fit of implant-supported complete-arch fixed prosthesis frameworks made of high-performance polymers and titanium: An explorative in-vitro study.
Abou-Ayash, Samir; Schimmel, Martin; Özcan, Mutlu; Ozcelik, Burak; Brägger, Urs; Yilmaz, Burak.
Afiliação
  • Abou-Ayash S; Senior Lecturer and Head of the Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Freiburgstrasse 7, 3007 Bern, Switzerland. Electronic address: samir.abou-ayash@zmk.unibe.ch.
  • Schimmel M; Department Head, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Freiburgstrasse 7, 3007 Bern, Switzerland; Senior lecturer, Extra muros, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzer
  • Özcan M; Head, Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental, University of Zurich, Zurich, Switzerland. Electronic address: mutlu.ozcan@zzm.uzh.ch.
  • Ozcelik B; Burak Ozcelik Professor, Baskent University Faculty of Dentistry Department of Prosthodontics, Ankara, Turkey. Electronic address: tbozcelik@yahoo.com.
  • Brägger U; Professor emeritus, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Freiburgstrasse 7, 3007 Bern, Switzerland. Electronic address: urs.braegger@zmk.unibe.ch.
  • Yilmaz B; Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3007 Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern,
J Dent ; 113: 103784, 2021 10.
Article em En | MEDLINE | ID: mdl-34419479
ABSTRACT

PURPOSE:

To investigate the trueness and marginal fit of computer-aided design-computer-aided manufactured (CAD-CAM) complete-arch implant-supported screw-retained fixed prosthesis (CAISFP) made of polyetheretherketone (PEEK), polyetherketoneketone (PEKK) and titanium (Ti) MATERIAL AND

METHODS:

A typodont model with four implants, their multiunit abutments (MUAs), and MUA scanbodies were digitized by using a laboratory scanner. The generated CAD was used to mill CAISFP frameworks in Ti, PEEK, or PEKK (each n = 10). The frameworks were digitized with an industrial light scanner to superimpose resulting standard tessellation language (STL) file with the CAD file. Deviations at five points at the abutment-framework interface of each of the four abutment sites (1left first molar, 2left canine, 3right canine, 4right first molar sites) were calculated (trueness). Marginal gaps were measured using the triple scan technique. A nonparametric repeated measures ANOVA by Brunner and Puri with factors being abutment location and material was performed to assess the mean deviations for trueness and mean marginal gaps, followed by Mann-Whitney or exact Wilcoxon Signed-Rank tests (alpha=.05).

RESULTS:

Material type significantly affected the trueness (p<0.0001). PEEK had the lowest deviations (0.039 +/-0.01mm) followed by PEKK (0,049 +/-0.009mm), and Ti (0.074 +/-0.011mm). For marginal gaps, only abutment location's effect was significant (p = 0.003). Within PEKK, gaps at abutment 4 were significantly larger, compared with abutments 2 (p = 0.04) and 3 (p = 0.02).

CONCLUSIONS:

The trueness of PEEK, PEKK, and Ti frameworks was different after milled. PEEK had the highest trueness. However, the marginal fit of the frameworks was similar and smaller than 90 µm in average. CLINICAL RELEVANCE PEEK, PEKK, and Ti complete-arch frameworks had clinically acceptable gaps and may therefore be recommended when their fit is considered. Higher trueness after milling did not result in better marginal fit.