Your browser doesn't support javascript.
loading
Diagnostic Value of Hounsfield Unit and Hematocrit Levels in Cerebral Vein Thrombosis in the Emergency Department.
Canakci, Mustafa Emin; Acar, Nurdan; Kuas, Caglar; Ozakin, Engin; Tiryaki Bastug, Betul; Karakilic, Evvah; Ozdemir, Atilla Ozcan.
Afiliação
  • Canakci ME; Emergency Department, Eskisehir Osmangazi University, Eskisehir, Turkey.
  • Acar N; Emergency Department, Eskisehir Osmangazi University, Eskisehir, Turkey.
  • Kuas C; Emergency Department, Yildirim Beyazit University Yenimahalle Training and Research Hospital, Ankara, Turkey.
  • Ozakin E; Emergency Department, Eskisehir Osmangazi University, Eskisehir, Turkey.
  • Tiryaki Bastug B; Radiology Department, Eskisehir Osmangazi University, Eskisehir, Turkey.
  • Karakilic E; Emergency Department, Eskisehir Osmangazi University, Eskisehir, Turkey.
  • Ozdemir AO; Neurology Department, Eskisehir Osmangazi University, Eskisehir, Turkey.
J Emerg Med ; 61(3): 234-240, 2021 09.
Article em En | MEDLINE | ID: mdl-34429219
BACKGROUND: Unenhanced computed tomography (CT) is a frequently used imaging method in patients who are evaluated in the emergency department with suspected cerebral vein thrombosis (CVT). OBJECTIVES: The aim of this study was to investigate the usefulness of the Hounsfield unit (HU) value determined by CT and its ratio to the patient's hematocrit (Htc) value in the diagnosis of cerebral vein thrombosis. METHODS: This retrospective study evaluated 41 patients with acute cerebral venous sinus thrombosis and 41 age- and sex-matched control participants. Two experienced observers independently evaluated the CT scan and measured the attenuation of the dural sinuses. RESULTS: There was no significant difference in age, gender, hemoglobin, and Htc values between the two groups. The mean HU value was 75 ± 7 HU in the CVT group and 52 ± 6 HU in the control group (p < 0.001). The mean HU/Htc ratio was 1.9 ± 0.3 in the CVT group and 1.3 ± 0.1 in the control group (p < 0.001). The optimal threshold value for HU was determined as 66, and sensitivity at this value was 93%, and specificity was 98%. The optimal threshold value for HU/Htc was determined as 1.64, and the sensitivity at this value was 90% and the specificity was 100%. CONCLUSION: Hyperattenuation in the dural sinuses and the HU/Htc ratio in unenhanced brain CT scans have high diagnostic value in detecting CVT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Veias Cerebrais Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: J Emerg Med Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Trombose / Veias Cerebrais Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: J Emerg Med Ano de publicação: 2021 Tipo de documento: Article