Your browser doesn't support javascript.
loading
Nano-Microscopy of Therapeutic Antibody Aggregates in Solution.
Senga, Yukako; Ogura, Toshihiko; Imamura, Hiroshi; Honda, Shinya.
Afiliação
  • Senga Y; Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan.
  • Ogura T; Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan.
  • Imamura H; Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan.
  • Honda S; Department of Applied Chemistry, College of Life Sciences Ritsumeikan University, Kusatsu, Shiga, Japan.
Methods Mol Biol ; 2313: 219-239, 2022.
Article em En | MEDLINE | ID: mdl-34478141
ABSTRACT
Scanning electron-assisted dielectric microscopy (SE-ADM) is a new microscope technology developed to observe the fine structure of biological samples in aqueous solution. One main advantage of SE-ADM is that it does not require sample pretreatment, including dehydration, drying, and staining, which is indispensable in conventional scanning electron microscopy (SEM) and can cause sample deformation. In addition, the sample is not directly irradiated with an electron beam in SE-ADM, further avoiding damage. The resolution of SE-ADM is higher than that of an optical microscope, which is typically used for observing biological samples in a solution, allowing for the observation of the detailed structure of samples. Considering these advantages, we applied SE-ADM to observe aggregates of therapeutic immunoglobulin G (IgG) of various sizes and shapes in an aqueous solution. In this chapter, we outline the step-by-step procedure for observing aggregates of monoclonal antibodies using SE-ADM and the subsequent analysis of the particle distribution and calculation of the fractal dimension using SE-ADM image data. The proposed method for particle analysis is highly reliable with respect to size measurement and can determine the diameter of a sample with an accuracy of ±20%, a precision of ±10%, and a lower limit of quantification of ≤50 nm. Further, by calculating the fractal dimension of the image, it is possible to classify the shape of the aggregates and determine the mechanism of aggregation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microscopia Eletrônica de Varredura Idioma: En Revista: Methods Mol Biol Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microscopia Eletrônica de Varredura Idioma: En Revista: Methods Mol Biol Ano de publicação: 2022 Tipo de documento: Article