Your browser doesn't support javascript.
loading
Atrial fibrillation detection in primary care during blood pressure measurements and using a smartphone cardiac monitor.
Sluyter, John D; Scragg, Robert; 'Ofanoa, Malakai; Stewart, Ralph A H.
Afiliação
  • Sluyter JD; School of Population Health, University of Auckland, Private Bag 92019, Auckland, New Zealand. j.sluyter@auckland.ac.nz.
  • Scragg R; School of Population Health, University of Auckland, Private Bag 92019, Auckland, New Zealand.
  • 'Ofanoa M; School of Population Health, University of Auckland, Private Bag 92019, Auckland, New Zealand.
  • Stewart RAH; Green Lane Cardiovascular Service, Auckland City Hospital, Auckland, New Zealand.
Sci Rep ; 11(1): 17721, 2021 09 06.
Article em En | MEDLINE | ID: mdl-34489508
ABSTRACT
Improved atrial fibrillation (AF) screening methods are required. We detected AF with pulse rate variability (PRV) parameters using a blood pressure device (BP+; Uscom, Sydney, Australia) and with a Kardia Mobile Cardiac Monitor (KMCM; AliveCor, Mountain View, CA). In 421 primary care patients (mean (range) age 72 (31-99) years), we diagnosed AF (n = 133) from 12-lead electrocardiogram recordings, and performed PRV and KMCM measurements. PRV parameters detected AF with area under curve (AUC) values of up to 0.92. Using the mean of two sequential readings increased AUC to up to 0.94 and improved positive predictive value at a given sensitivity (by up to 18%). The KMCM detected AF with 83% sensitivity and 68% specificity. 89 KMCM recordings were "unclassified" or blank, and PRV detected AF in these with AUC values of up to 0.88. When non-AF arrhythmias (n = 56) were excluded, the KMCM device had increased specificity (73%) and PRV had higher discrimination performance (maximum AUC = 0.96). In decision curve analysis, all PRV parameters consistently achieved a positive net benefit across the range of clinical thresholds. In primary care, AF can be detected by PRV accurately and by KMCM, especially in the absence of non-AF arrhythmias or when combinations of measurements are used.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Atenção Primária à Saúde / Fibrilação Atrial / Pressão Sanguínea / Smartphone Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Atenção Primária à Saúde / Fibrilação Atrial / Pressão Sanguínea / Smartphone Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Humans / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article