Your browser doesn't support javascript.
loading
Novel Speckle Tracking Analysis Showed Excellent Reproducibility for Size and Shape of the Fetal Heart and Good Reproducibility for Strain and Fractional Shortening.
Huntley, Erin S; Hernandez-Andrade, Edgar; Soto, Eleazar; DeVore, Gregory; Sibai, Baha M.
Afiliação
  • Huntley ES; Department of Obstetrics and Gynecology and Reproductive Sciences, McGovern Medical School, University of Texas, Health Science Center at Houston (UTHealth), Houston, Texas, USA.
  • Hernandez-Andrade E; Department of Obstetrics and Gynecology and Reproductive Sciences, McGovern Medical School, University of Texas, Health Science Center at Houston (UTHealth), Houston, Texas, USA.
  • Soto E; Department of Obstetrics and Gynecology and Reproductive Sciences, McGovern Medical School, University of Texas, Health Science Center at Houston (UTHealth), Houston, Texas, USA.
  • DeVore G; Fetal Diagnostic Centers, Pasadena, California, USA.
  • Sibai BM; Department of Obstetrics and Gynecology, David Geffen School of Medicine, UCLA, Los Angeles, California, USA.
Fetal Diagn Ther ; 48(7): 541-550, 2021.
Article em En | MEDLINE | ID: mdl-34515112
ABSTRACT

INTRODUCTION:

This study aimed to evaluate reproducibility and agreement of fetal cardiac shape and deformation using FetalHQ.

METHODS:

Fifty normal fetuses at 20-38 weeks of gestation were evaluated. Two operators independently selected an optimal cardiac cycle using FetalHQ®™software for speckle tracking analysis. Intra- and interobserver correlation coefficient and limits of agreement for cardiac shape and deformation were estimated.

RESULTS:

Global cardiac markers high correlation (r = 0.98) and agreement (mean difference, standard deviation [MD, SD] 5.07, 75.8) for ventricular area; moderate correlation (r = 0.78) and agreement (MD, SD 0.016, 0.08) for global sphericity index (SI) and for left ventricle (LV) global strain (r = 0.65; MD, SD -4.48, 11.9); and low but still significant correlation (r = 0.58) and agreement (MD, SD -3.77, 12.27) for right ventricle (RV) global strain. For individual ventricular parameters high correlation for LV ([median r; range] 0.98; 0.93-0.99) and RV (r = 0.98; 0.97-1.0) SI, and for LV (r = 0.92 0.56-0.99) and RV (r = 0.96; 0.67-0.99) end diastolic diameters; moderate correlation for LV fractional shortening (r = 0.53; 0.87-0.98); and no significant correlation for RV fractional shortening (r = 0.36; 0.32-0.97). Inter- and intraobserver correlation and agreement were similar for all evaluated parameters.

CONCLUSION:

Speckle tracking analysis of the fetal heart provides reliable estimations of global and LV shape and deformation. Low correlation in the RV can be related to anatomical structures such as the moderator band.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ultrassonografia Pré-Natal / Coração Fetal Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: Fetal Diagn Ther Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ultrassonografia Pré-Natal / Coração Fetal Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: Fetal Diagn Ther Ano de publicação: 2021 Tipo de documento: Article