Efficacy of facemasks in mitigating respiratory exposure to submicron aerosols.
Sharma, Ashish; Omidvarborna, Hamid; Kumar, Prashant.
Afiliação
  • Sharma A; Global Centre for Clean Air Research (GCARE), Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom.
  • Omidvarborna H; Global Centre for Clean Air Research (GCARE), Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom.
  • Kumar P; Global Centre for Clean Air Research (GCARE), Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom. Electronic address: p.kumar@surrey.ac.uk.
J Hazard Mater ; 422: 126783, 2022 01 15.
Article em En | MEDLINE | ID: mdl-34523504
ABSTRACT
We designed a novel experimental set-up to pseudo-simultaneously measure size-segregated filtration efficiency (ηF), breathing resistance (ηP) and potential usage time (tB) for 11 types of face protective equipment (FPE; four respirators; three medical; and four handmade) in the submicron range. As expected, the highest ηF was exhibited by respirators (97 ± 3%), followed by medical (81 ± 7%) and handmade (47 ± 13%). Similarly, the breathing resistance was highest for respirators, followed by medical and handmade FPE. Combined analysis of efficiency and breathing resistance highlighted trade-offs, i.e. respirators showing the best overall performance across these two indicators, followed by medical and handmade FPE. This hierarchy was also confirmed by quality factor, which is a performance indicator of filters. Detailed assessment of size-segregated aerosols, combined with the scanning electron microscope imaging, revealed material characteristics such as pore density, fiber thickness, filter material and number of layers influence their performance. ηF and ηP showed an inverse exponential decay with time. Using their cross-over point, in combination with acceptable breathability, allowed to estimate tB as 3.2-9.5 h (respirators), 2.6-7.3 h (medical masks) and 4.0-8.8 h (handmade). While relatively longer tB of handmade FPE indicate breathing comfort, they are far less efficient in filtering virus-laden submicron aerosols compared with respirators.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Proteção Respiratória / Máscaras Idioma: En Revista: J Hazard Mater Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Proteção Respiratória / Máscaras Idioma: En Revista: J Hazard Mater Ano de publicação: 2022 Tipo de documento: Article