Your browser doesn't support javascript.
loading
Heterogeneous material mapping methods for patient-specific finite element models of pelvic trabecular bone: A convergence study.
Babazadeh Naseri, Ata; Dunbar, Nicholas J; Baines, Andrew J; Akin, John E; Higgs Iii, C Fred; Fregly, Benjamin J.
Afiliação
  • Babazadeh Naseri A; Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA.
  • Dunbar NJ; Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA.
  • Baines AJ; Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA.
  • Akin JE; Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA.
  • Higgs Iii CF; Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA.
  • Fregly BJ; Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA. Electronic address: fregly@rice.edu.
Med Eng Phys ; 96: 1-12, 2021 10.
Article em En | MEDLINE | ID: mdl-34565547
ABSTRACT
Patient-specific finite element (FE) models of bone require the assignment of heterogeneous material properties extracted from the subject's computed tomography (CT) images. Though node-based (NB) and element-based (EB) material mapping methods (MMMs) have been proposed, the sensitivity and convergence of FE models to MMM for varying mesh sizes are not well understood. In this work, CT-derived and synthetic bone material data were used to evaluate the effect of MMM on results from FE analyses. Pelvic trabecular bone data was extracted from CT images of six subjects, while synthetic data were created to resemble trabecular bone properties. The numerical convergence of FE bone models using different MMMs were evaluated for strain energy, von-Mises stress, and strain. NB and EB MMMs both demonstrated good convergence regarding total strain energy, with the EB method having a slight edge over the NB. However, at the local level (e.g., maximum stress and strain), FE results were sensitive to the field type, MMM, and the FE mesh size. The EB method exhibited superior performance in finer meshes relative to the voxel size. The NB method converged better than did the EB method for coarser meshes. These findings may lead to higher-fidelity patient-specific FE bone models.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Osso Esponjoso Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Med Eng Phys Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Osso Esponjoso Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Med Eng Phys Ano de publicação: 2021 Tipo de documento: Article