Your browser doesn't support javascript.
loading
Clinical Validation of Fetal cfDNA Analysis Using Rolling-Circle-Replication and Imaging Technology in Osaka (CRITO Study).
Pooh, Ritsuko Kimata; Masuda, Chika; Matsushika, Risa; Machida, Megumi; Nakamura, Takako; Takeda, Masayoshi; Ohashi, Hiroyasu; Kumagai, Mami; Uenishi, Kohtaro; Roos, Fredrik; Persson, Fredrik; Shimokawa, Osamu.
Afiliação
  • Pooh RK; Clinical Laboratory, Ritz Medical Co., Ltd., Osaka 543-0001, Japan.
  • Masuda C; CRIFM Prenatal Medical Clinic, Osaka 543-0001, Japan.
  • Matsushika R; Clinical Laboratory, Ritz Medical Co., Ltd., Osaka 543-0001, Japan.
  • Machida M; Clinical Laboratory, Ritz Medical Co., Ltd., Osaka 543-0001, Japan.
  • Nakamura T; CRIFM Prenatal Medical Clinic, Osaka 543-0001, Japan.
  • Takeda M; CRIFM Prenatal Medical Clinic, Osaka 543-0001, Japan.
  • Ohashi H; Clinical Laboratory, Ritz Medical Co., Ltd., Osaka 543-0001, Japan.
  • Kumagai M; Clinical Laboratory, Ritz Medical Co., Ltd., Osaka 543-0001, Japan.
  • Uenishi K; Clinical Laboratory, Ritz Medical Co., Ltd., Osaka 543-0001, Japan.
  • Roos F; Clinical Laboratory, Ritz Medical Co., Ltd., Osaka 543-0001, Japan.
  • Persson F; Vanadis Diagnostics, PerkinElmer Inc., 191 38 Sollentuna, Sweden.
  • Shimokawa O; Vanadis Diagnostics, PerkinElmer Inc., 191 38 Sollentuna, Sweden.
Diagnostics (Basel) ; 11(10)2021 Oct 04.
Article em En | MEDLINE | ID: mdl-34679535
ABSTRACT

BACKGROUND:

Noninvasive prenatal genetic testing (NIPT) has been adopted as the first choice for aneuploidy screening. The purposes of this study were to investigate the accuracy of Vanadis® NIPT (hereafter CRITO-NIPT) in order to gain a deeper insight into the reasons for discrepancies, as well as to discuss the role of fetal ultrasound.

METHODS:

Between 2019 and 2020, CRITO-NIPT was performed in 1218 cases of patients who underwent CVS or amniocentesis after a detailed fetal ultrasound exam and genetic counseling. The CRITO-NIPT results were compared with the genetic results. In cases of test discrepancies, the placentae were collected for detailed genetic research, and the pre-procedure fetal ultrasound findings were referred to.

RESULTS:

The positive predictive value of T21, T18, and T13 was 93.55%, 88.46%, and 100%, respectively. In 90% of the of false positive (FP) cases, the placentae were examined. In 75% of the CRITO FP-T21 cases, placental mosaicism, or a demised twin's T21, were confirmed. There were complicated mosaic cases, including tetrasomy 21/trisomy7 and monosomy 21/trisomy21 cases. In one of three no-call cases, an intermediate deletion of chromosome 13 was detected.

CONCLUSIONS:

The CRITO study investigated the mechanism of false positives, and the detailed mechanisms in mosaic and no-call cases. There have hitherto been no reports that have provided insight by partitioning the placenta to compare the NIPT and invasive test results, nor that have provided detailed ultrasound findings in the cases of discordant results, revealing the demonstrated importance of, and necessity for, detailed ultrasonography. This article describes the potential of rolling-circle replication as a powerful biosensing platform, as well as the importance of examining the fetus in detail with ultrasound. However, we should remember that the potential applications raise ethical and social concerns that go beyond aneuploidy and its methodology.