Your browser doesn't support javascript.
loading
Inter- and Intra-Scanner Variability of Automated Brain Volumetry on Three Magnetic Resonance Imaging Systems in Alzheimer's Disease and Controls.
Wittens, Mandy Melissa Jane; Allemeersch, Gert-Jan; Sima, Diana Maria; Naeyaert, Maarten; Vanderhasselt, Tim; Vanbinst, Anne-Marie; Buls, Nico; De Brucker, Yannick; Raeymaekers, Hubert; Fransen, Erik; Smeets, Dirk; van Hecke, Wim; Nagels, Guy; Bjerke, Maria; de Mey, Johan; Engelborghs, Sebastiaan.
Afiliação
  • Wittens MMJ; Reference Center for Biological Markers of Dementia, Laboratory of Neurochemistry and Behavior, University of Antwerp, Antwerp, Belgium.
  • Allemeersch GJ; Center for Neurosciences (C4N) and Department of Neurology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • Sima DM; Department of Radiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • Naeyaert M; Icometrix, Leuven, Belgium.
  • Vanderhasselt T; Department of Radiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • Vanbinst AM; Department of Radiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • Buls N; Department of Radiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • De Brucker Y; Department of Radiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • Raeymaekers H; Department of Radiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • Fransen E; Department of Radiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • Smeets D; StatUa Center for Statistics, University of Antwerp, Antwerp, Belgium.
  • van Hecke W; Icometrix, Leuven, Belgium.
  • Nagels G; Icometrix, Leuven, Belgium.
  • Bjerke M; Center for Neurosciences (C4N) and Department of Neurology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • de Mey J; Reference Center for Biological Markers of Dementia, Laboratory of Neurochemistry and Behavior, University of Antwerp, Antwerp, Belgium.
  • Engelborghs S; Center for Neurosciences (C4N) and Department of Neurology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium.
Front Aging Neurosci ; 13: 746982, 2021.
Article em En | MEDLINE | ID: mdl-34690745
ABSTRACT
Magnetic Resonance Imaging (MRI) has become part of the clinical routine for diagnosing neurodegenerative disorders. Since acquisitions are performed at multiple centers using multiple imaging systems, detailed analysis of brain volumetry differences between MRI systems and scan-rescan acquisitions can provide valuable information to correct for different MRI scanner effects in multi-center longitudinal studies. To this end, five healthy controls and five patients belonging to various stages of the AD continuum underwent brain MRI acquisitions on three different MRI systems (Philips Achieva dStream 1.5T, Philips Ingenia 3T, and GE Discovery MR750w 3T) with harmonized scan parameters. Each participant underwent two subsequent MRI scans per imaging system, repeated on three different MRI systems within 2 h. Brain volumes computed by icobrain dm (v5.0) were analyzed using absolute and percentual volume differences, Dice similarity (DSC) and intraclass correlation coefficients, and coefficients of variation (CV). Harmonized scans obtained with different scanners of the same manufacturer had a measurement error closer to the intra-scanner performance. The gap between intra- and inter-scanner comparisons grew when comparing scans from different manufacturers. This was observed at image level (image contrast, similarity, and geometry) and translated into a higher variability of automated brain volumetry. Mixed effects modeling revealed a significant effect of scanner type on some brain volumes, and of the scanner combination on DSC. The study concluded a good intra- and inter-scanner reproducibility, as illustrated by an average intra-scanner (inter-scanner) CV below 2% (5%) and an excellent overlap of brain structure segmentation (mean DSC > 0.88).
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Observational_studies Idioma: En Revista: Front Aging Neurosci Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Observational_studies Idioma: En Revista: Front Aging Neurosci Ano de publicação: 2021 Tipo de documento: Article