Your browser doesn't support javascript.
loading
A new open-path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections.
Pan, Da; Gelfand, Ilya; Tao, Lei; Abraha, Michael; Sun, Kang; Guo, Xuehui; Chen, Jiquan; Robertson, G Philip; Zondlo, Mark A.
Afiliação
  • Pan D; Department of Civil and Environmental Engineering, Princeton University, Princeton, New Jersey, USA.
  • Gelfand I; Center for Mid-Infrared Technologies for Health and the Environmental, NSF-ERC, Princeton, New Jersey, USA.
  • Tao L; Great Lakes Bioenergy Research Center, Michigan State University, East Lansing, Michigan, USA.
  • Abraha M; W.K. Kellogg Biological Station, Michigan State University, Hickory Corners, Michigan, USA.
  • Sun K; The French Associates Institute for Agriculture and Biotechnology of Drylands, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Beer-Sheva, Israel.
  • Guo X; Department of Civil and Environmental Engineering, Princeton University, Princeton, New Jersey, USA.
  • Chen J; Center for Mid-Infrared Technologies for Health and the Environmental, NSF-ERC, Princeton, New Jersey, USA.
  • Robertson GP; Great Lakes Bioenergy Research Center, Michigan State University, East Lansing, Michigan, USA.
  • Zondlo MA; W.K. Kellogg Biological Station, Michigan State University, Hickory Corners, Michigan, USA.
Glob Chang Biol ; 28(4): 1446-1457, 2022 02.
Article em En | MEDLINE | ID: mdl-34758177
ABSTRACT
Low-power, open-path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open-path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser-based, open-path sensors with the needed sensitivity for trace gases like methane (CH4 ) and nitrous oxide (N2 O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N2 O fluxes. Consequently, measuring background fluxes with laser-based, open-path sensors is extremely challenging, particularly for N2 O and gases with similar high-precision requirements. We demonstrate a new laser-based, open-path N2 O sensor and a general approach applicable to other gases that minimizes temperature-related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open-path N2 O sensor was tested at a corn (Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature-related corrections were 6% of density corrections, reducing EC random errors by 20-fold compared to previously examined lines. Measured open-path N2 O EC fluxes showed excellent agreement with those made with static chambers (m = 1.0 ± 0.3; r2  = .96). More generally, we identified absorption lines for CO2 and CH4  flux measurements that can reduce the temperature-related corrections by 10-100 times compared to existing open-path sensors. The proposed method provides a new direction for future open-path sensors, facilitating the expansion of accurate EC flux measurements.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Gases / Óxido Nitroso Idioma: En Revista: Glob Chang Biol Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Gases / Óxido Nitroso Idioma: En Revista: Glob Chang Biol Ano de publicação: 2022 Tipo de documento: Article