Your browser doesn't support javascript.
loading
Comparison of liver scintigraphy and the liver-spleen contrast in Gd-EOB-DTPA-enhanced MRI on liver function tests.
Mori, Hiroshige; Machimura, Hanaka; Iwaya, Amika; Baba, Masaru; Furuya, Ken.
Afiliação
  • Mori H; Department of Radiology, Japan Community Healthcare Organization Hokkaido Hospital, 1-8-3-18 Nakanoshima, Toyohira, Sapporo, Hokkaido, 062-8618, Japan. mori-hiroshige@hokkaido.jcho.go.jp.
  • Machimura H; Department of Radiology, Japan Community Healthcare Organization Hokkaido Hospital, 1-8-3-18 Nakanoshima, Toyohira, Sapporo, Hokkaido, 062-8618, Japan.
  • Iwaya A; Department of Radiology, Japan Community Healthcare Organization Hokkaido Hospital, 1-8-3-18 Nakanoshima, Toyohira, Sapporo, Hokkaido, 062-8618, Japan.
  • Baba M; Center for Gastroenterology and Hepatology, Japan Community Healthcare Organization Hokkaido Hospital, 1-8-3-18 Nakanoshima, Toyohira, Sapporo, Hokkaido, 062-8618, Japan. m-baba@piano.ocn.ne.jp.
  • Furuya K; Center for Gastroenterology and Hepatology, Japan Community Healthcare Organization Hokkaido Hospital, 1-8-3-18 Nakanoshima, Toyohira, Sapporo, Hokkaido, 062-8618, Japan.
Sci Rep ; 11(1): 22472, 2021 11 18.
Article em En | MEDLINE | ID: mdl-34795343
ABSTRACT
The liver-spleen contrast (LSC) using hepatobiliary-phase images could replace the receptor index (LHL15) in liver scintigraphy; however, few comparative studies exist. This study aimed to verify the convertibility from LSC into LHL15. In 136 patients, the LSC, not at 20 min, but at 60 min after injecting gadolinium-ethoxybenzyl-diethylenetriaminepentaacetic acid was compared with the LHL15, albumin-bilirubin (ALBI) score, and the related laboratory parameters. The LHL15 was also compared with their biochemical tests. The correlation coefficients of LSC with LHL15, ALBI score, total bilirubin, and albumin were 0.740, -0.624, -0.606, and 0.523 (P < 0.00001), respectively. The correlation coefficients of LHL15 with ALBI score, total bilirubin, and albumin were -0.647, -0.553, and 0.569 (P < 0.00001), respectively. The linear regression equation on the estimated LHL15 (eLHL15) from LSC was eLHL15 = 0.460 · LSC + 0.727 (P < 0.00001) and the coefficient of determination was 0.548. Regarding a contingency table using imaging-based clinical stage classification, the degree of agreement between eLHL15 and LHL15 was 65.4%, and Cramer's V was 0.568 (P < 0.00001). Therefore, although the LSC may be influenced by high total bilirubin, the eLHL15 can replace the LSC as an index to evaluate liver function.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Baço / Imageamento por Ressonância Magnética / Cintilografia / Gadolínio DTPA / Fígado Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Baço / Imageamento por Ressonância Magnética / Cintilografia / Gadolínio DTPA / Fígado Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article