Assessing changes to N95 respirator filtration efficiency, qualitative and quantitative fit, and seal check with repeated vaporized hydrogen peroxide (VHP) decontamination.
Yen, Christina F; Seeley, Robert; Gordon, Patrick; Parameswaran, Lalitha; Wright, Sharon B; Pepe, Dana E; Mehrotra, Preeti.
Afiliação
  • Yen CF; Division of Infection Control/Hospital Epidemiology, Silverman Institute of Health Care Quality & Safety, Beth Israel Deaconess Medical Center, Boston, MA; Division of Infectious Diseases, Beth Israel Deaconess Medical Center, Boston, MA. Electronic address: christfyen@gmail.com.
  • Seeley R; Department of Environmental Health and Safety, Beth Israel Deaconess Medical Center, Boston, MA.
  • Gordon P; Division of Infection Control/Hospital Epidemiology, Silverman Institute of Health Care Quality & Safety, Beth Israel Deaconess Medical Center, Boston, MA.
  • Parameswaran L; Massachusetts Institute of Technology, Lincoln Laboratory, Lexington, MA.
  • Wright SB; Division of Infection Control/Hospital Epidemiology, Silverman Institute of Health Care Quality & Safety, Beth Israel Deaconess Medical Center, Boston, MA; Division of Infectious Diseases, Beth Israel Deaconess Medical Center, Boston, MA.
  • Pepe DE; Division of Infection Control/Hospital Epidemiology, Silverman Institute of Health Care Quality & Safety, Beth Israel Deaconess Medical Center, Boston, MA; Division of Infectious Diseases, Beth Israel Deaconess Medical Center, Boston, MA.
  • Mehrotra P; Division of Infection Control/Hospital Epidemiology, Silverman Institute of Health Care Quality & Safety, Beth Israel Deaconess Medical Center, Boston, MA; Division of Infectious Diseases, Beth Israel Deaconess Medical Center, Boston, MA.
Am J Infect Control ; 50(2): 217-219, 2022 02.
Article em En | MEDLINE | ID: mdl-35000800
N95 respirators were reprocessed using vaporized hydrogen peroxide to supplement limited supplies during the COVID-19 pandemic. In this study, we found no statistically significant differences in qualitative and quantitative fit or filtration efficiency with reprocessing. Filtration efficiency remained above 95% even at 25 cycles of reprocessing without statistically significant change from cycle 20-25 compared to cycle 0 (P = .10, P = .05, respectively). Vaporous hydrogen peroxide is an effective option to augment N95 respirator supplies.