Your browser doesn't support javascript.
loading
Enhanced Physicochemical and Biological Properties of a Low-Temperature Copperized Layer on Gradient Nanograined Pure Titanium.
Qiu, Jing; Pan, Ting; Peng, Mengxia; Chen, Mian; Xu, Jilin; Wang, Jie; Wan, Yizao; Hu, Jian.
Afiliação
  • Qiu J; Institute of Advanced Materials, East China Jiaotong University, Nanchang 330013, China.
  • Pan T; Jiangxi Key Laboratory of Nanobiomaterials, East China Jiaotong University, Nanchang 330013, China.
  • Peng M; Institute of Advanced Materials, East China Jiaotong University, Nanchang 330013, China.
  • Chen M; Jiangxi Key Laboratory of Nanobiomaterials, East China Jiaotong University, Nanchang 330013, China.
  • Xu J; Institute of Advanced Materials, East China Jiaotong University, Nanchang 330013, China.
  • Wang J; Jiangxi Key Laboratory of Nanobiomaterials, East China Jiaotong University, Nanchang 330013, China.
  • Wan Y; Institute of Advanced Materials, East China Jiaotong University, Nanchang 330013, China.
  • Hu J; Jiangxi Key Laboratory of Nanobiomaterials, East China Jiaotong University, Nanchang 330013, China.
ACS Appl Bio Mater ; 4(4): 3524-3531, 2021 04 19.
Article em En | MEDLINE | ID: mdl-35014437
ABSTRACT
The application of titanium as medical implants is limited to a certain extent due to its insufficient corrosion resistance, biological activity, and antibacterial ability. In this work, a gradient nanograined (GNG) layer was fabricated on the titanium surface by surface ultrasonic rolling treatment (SURT). The subsequent copperizing kinetics was greatly enhanced so that a thick copperized layer could be obtained on the surface of GNG Ti at a relatively low diffusion temperature (450 °C). Meanwhile, the GNG structure accelerated the release rate of Cu2+, which endows GNG Cu/Ti with strong antibacterial activity. Moreover, the corrosion resistance and cytocompatibility of GNG Cu/Ti were also evidently improved compared with coarse-grained Ti, indicating a good biomedical application prospect.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Assunto principal: Temperatura / Titânio / Materiais Biocompatíveis / Cobre / Antibacterianos Idioma: En Revista: ACS Appl Bio Mater Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Assunto principal: Temperatura / Titânio / Materiais Biocompatíveis / Cobre / Antibacterianos Idioma: En Revista: ACS Appl Bio Mater Ano de publicação: 2021 Tipo de documento: Article