Your browser doesn't support javascript.
loading
Short echo time dual-frequency MR Elastography with Optimal Control RF pulses.
Sango-Solanas, Pilar; Tse Ve Koon, Kevin; Van Reeth, Eric; Ratiney, Helene; Millioz, Fabien; Caussy, Cyrielle; Beuf, Olivier.
Afiliação
  • Sango-Solanas P; Univ Lyon, INSA Lyon, Inserm, UCBL, CNRS, CREATIS, UMR5220, U1294, 69621, Villeurbanne, France.
  • Tse Ve Koon K; Univ Lyon, INSA Lyon, Inserm, UCBL, CNRS, CREATIS, UMR5220, U1294, 69621, Villeurbanne, France.
  • Van Reeth E; Univ Lyon, INSA Lyon, Inserm, UCBL, CNRS, CREATIS, UMR5220, U1294, 69621, Villeurbanne, France.
  • Ratiney H; CPE Lyon, Département Sciences du Numérique, Lyon, France.
  • Millioz F; Univ Lyon, INSA Lyon, Inserm, UCBL, CNRS, CREATIS, UMR5220, U1294, 69621, Villeurbanne, France.
  • Caussy C; Univ Lyon, INSA Lyon, Inserm, UCBL, CNRS, CREATIS, UMR5220, U1294, 69621, Villeurbanne, France.
  • Beuf O; Univ Lyon, INSERM, INRA, INSA Lyon, UCBL, CarMen Laboratory, 69495, Pierre-Bénite, France.
Sci Rep ; 12(1): 1406, 2022 01 26.
Article em En | MEDLINE | ID: mdl-35082303
ABSTRACT
Magnetic Resonance Elastography (MRE) quantifies the mechanical properties of tissues, typically applying motion encoding gradients (MEG). Multifrequency results allow better characterizations of tissues using data usually acquired through sequential monofrequency experiments. High frequencies are difficult to reach due to slew rate limitations and low frequencies induce long TEs, yielding magnitude images with low SNR. We propose a novel strategy to perform simultaneous multifrequency MRE in the absence of MEGs using RF pulses designed via the Optimal Control (OC) theory. Such pulses control the spatial distribution of the MRI magnetization phase so that the resulting transverse magnetization reproduces the phase pattern of an MRE acquisition. The pulse is applied with a constant gradient during the multifrequency mechanical excitation to simultaneously achieve slice selection and motion encoding. The phase offset sampling strategy can be adapted according to the excitation frequencies to reduce the acquisition time. Phantom experiments were run to compare the classical monofrequency MRE to the OC based dual-frequency MRE method and showed excellent agreement between the reconstructed shear storage modulus G'. Our method could be applied to simultaneously acquire low and high frequency components, which are difficult to encode with the classical MEG MRE strategy.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2022 Tipo de documento: Article