Your browser doesn't support javascript.
loading
Foreign body reaction mimicking local recurrence from polyactide adhesion barrier film after laparoscopic colorectal cancer surgery: A retrospective cohort study.
Hsieh, Tien-Chan; Hsu, Chao-Wen.
Afiliação
  • Hsieh TC; Division of Colorectal Surgery, Department of Surgery, Kaohsiung Veterans General Hospital, No. 386, Dazhong 1st Rd., Zuoying Dist., Kaohsiung City, Taiwan.
  • Hsu CW; Department of Medicine, Danbury Hospital, 24 Hospital Avenue, Danbury, CT.
Medicine (Baltimore) ; 101(5): e28692, 2022 Feb 04.
Article em En | MEDLINE | ID: mdl-35119013
ABSTRACT
ABSTRACT Polyactide (PLA) barrier is one of the most commonly used materials to prevent the formation of postoperative adhesion. Even though previous studies supported the anti-adhesion efficacy of PLA barrier, there have been limited reports focusing on the associated foreign body reaction. We sought to investigate the potential complication of PLA barrier placement that could lead to unnecessary intervention.This is a retrospective study of colorectal cancer patients with laparoscopic surgery. Cases with stage IV unresectable disease, poor Eastern Cooperative Oncology Group Performance, death within 3 months after the surgery, and insufficient record were excluded. A total of 296 cases were identified in our study and 220 patients received PLA film placement. We compared the incidence of foreign body reaction between the patients with and without PLA film.Among PLA film group, 16 cases had signs of local recurrence on the follow-up image studies. The subsequent operation found 10 patients had no cancerous lesions but only foreign-body-associated granulomas. The incidence of foreign body reaction mimicking local recurrence on image study was 4.5% with high false positive rate of 62.5% on positron emission tomography scan in patients with PLA film. There were only 2 cases without the antiadhesive barrier developed signs of recurrence during active surveillance. Both cases were later confirmed to have malignant peritoneal seeding.The PLA film was associated with rare foreign body reaction that could interfere the accuracy of follow-up program and result in unnecessary surgical intervention. Hence, we recommend avoiding the use of the PLA barrier.
Assuntos

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 / 2_ODS3 / 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Poliésteres / Neoplasias Colorretais / Reação a Corpo Estranho / Laparoscopia Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Medicine (Baltimore) Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 / 2_ODS3 / 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Poliésteres / Neoplasias Colorretais / Reação a Corpo Estranho / Laparoscopia Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Medicine (Baltimore) Ano de publicação: 2022 Tipo de documento: Article