A Community Outbreak of Legionnaires' Disease with Two Strains of L. pneumophila Serogroup 1 Linked to an Aquatic Therapy Centre.
Rousseau, Cyril; Ginevra, Christophe; Simac, Leslie; Fiard, Noel; Vilhes, Karine; Ranc, Anne-Gaëlle; Jarraud, Sophie; Gornes, Hervé; Mouly, Damien; Campese, Christine.
Afiliação
  • Rousseau C; The French Public Health Agency (Santé Publique France), Region Division-Occitanie, 31050 Toulouse, France.
  • Ginevra C; The National Reference Center of Legionella, 69317 Lyon, France.
  • Simac L; CIRI, Centre International de Recherche en Infectiologie, Inserm, U1111, Université Claude Bernard Lyon 1, CNRS, UMR5308, Ecole Normale Supérieure de Lyon, 69007 Lyon, France.
  • Fiard N; The French Public Health Agency (Santé Publique France), Region Division-Occitanie, 31050 Toulouse, France.
  • Vilhes K; The Regional Health Agency of Occitanie, 34000 Montpellier, France.
  • Ranc AG; The Regional Health Agency of Occitanie, 34000 Montpellier, France.
  • Jarraud S; The National Reference Center of Legionella, 69317 Lyon, France.
  • Gornes H; CIRI, Centre International de Recherche en Infectiologie, Inserm, U1111, Université Claude Bernard Lyon 1, CNRS, UMR5308, Ecole Normale Supérieure de Lyon, 69007 Lyon, France.
  • Mouly D; The National Reference Center of Legionella, 69317 Lyon, France.
  • Campese C; CIRI, Centre International de Recherche en Infectiologie, Inserm, U1111, Université Claude Bernard Lyon 1, CNRS, UMR5308, Ecole Normale Supérieure de Lyon, 69007 Lyon, France.
Article em En | MEDLINE | ID: mdl-35162143
ABSTRACT
An outbreak of Legionnaires' disease affected 18 people in Montpellier, a town of the south of France, between December 2016 and July 2017. All cases were diagnosed by a positive urinary antigen test. No deaths were reported. Epidemiological, environmental and genomic investigations (nested Sequence-Based Typing (nSBT) and whole genome sequencing) were undertaken. For the cases for which we had information, four had a new isolate (ST2471), one had a different new isolate (ST2470), one had a genomic pattern compatible with the ST2471 identified by nSBT (flaA = 3), and one had a genomic pattern not compatible with two previous identified STs (pilE = 6). The analysis conducted on the pool of an aquatic therapy center revealed seven isolates of Legionella pneumophila. Whole genome analysis confirmed the link between the environmental and clinical isolates for both ST2470 and ST2471. As the outbreak occurred slowly, with several weeks between new cases, it was not possible to immediately identify a common source. The sixth case was the first to report having aquatic therapy care. Of the 18 cases, eight had attended the aquatic therapy center and the other 10 were inhabitants who lived, worked or walked close to the center. The main cause for this outbreak was the lack of facility maintenance. This investigation highlights the risk to public health of aquatic therapy centers for users and nearby populations, and emphasizes the need for risk reduction measures with specific guidelines to improve health and safety in aquatic facilities.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 / 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Doença dos Legionários / Legionella pneumophila Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Int J Environ Res Public Health Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 / 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Doença dos Legionários / Legionella pneumophila Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Int J Environ Res Public Health Ano de publicação: 2022 Tipo de documento: Article