Your browser doesn't support javascript.
loading
Use of the 95-degree angled blade plate with biological and mechanical augmentation to treat proximal femur non-unions: a case series.
Vicenti, Giovanni; Solarino, Giuseppe; Bizzoca, Davide; Simone, Filippo; Maccagnano, Giuseppe; Zavattini, Giacomo; Ottaviani, Guglielmo; Carrozzo, Massimiliano; Buono, Claudio; Zaccari, Domenico; Moretti, Biagio.
Afiliação
  • Vicenti G; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy.
  • Solarino G; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy.
  • Bizzoca D; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy. da.bizzoca@gmail.com.
  • Simone F; University of Bari "Aldo Moro, PhD course in Public Health, Clinical Medicine, and Oncology, Piazza Giulio Cesare 11, 70100, Bari, Italy. da.bizzoca@gmail.com.
  • Maccagnano G; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy.
  • Zavattini G; Riuniti Hospital, Foggia, Italy.
  • Ottaviani G; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy.
  • Carrozzo M; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy.
  • Buono C; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy.
  • Zaccari D; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy.
  • Moretti B; Department of Basic Medical Sciences, Neuroscience and Sense Organs, School of Medicine, University of Bari "Aldo Moro", AOU Consorziale Policlinico, Orthopaedic & Trauma Unit, Bari, Italy.
BMC Musculoskelet Disord ; 22(Suppl 2): 1067, 2022 Feb 28.
Article em En | MEDLINE | ID: mdl-35227245
ABSTRACT

BACKGROUND:

Intertrochanteric and subtrochanteric non-union are rare but challenging complications. In the present study, we investigate the use of a 95° blade, in association with biological and mechanical augmentation, in the management of intertrochanteric and subtrochanteric femoral non-unions.

METHODS:

Between October 2015 and February 2021, a retrospective cohort study was conducted at our institution to investigate the use of a 95° blade, in association with biological and mechanical augmentation, in the management of intertrochanteric and subtrochanteric femoral non-unions, following the mechanical failure of the first device. All the patients underwent a clinical and radiographic follow-up at 6 weeks, 3, 6, 9, 12 and 18 months; at each follow-up, a plain radiograph of the femur was performed and patients were assessed using Harris Hip Score (HHS) and the Short Form-12 (SF-12) questionnaire.

RESULTS:

From October 2015 and February 2021, 40 proximal femur non-unions were managed at our Institution. Fifteen patients out of forty (37.5%) met the inclusion criteria. The main data of the study are summarized in Table 1; patients' mean was 57 years old (range 19-83); 10 males and 5 females were included in the study. All the patients completely healed clinically and radiologically at an average of 6.1 months (range 4-13). All these patients returned to their pre-injury mobility status. During an average follow-up period of 25 months (range 8-60), the observed complications included wound dehiscence, which was treated with a superficial surgical debridement, a below-the-knee deep vein thrombosis, and a blade plate failure 3 months after the first revision surgery.

CONCLUSIONS:

This study shows the treatment of inter-and sub-trochanteric non-unions with a 95° blade plate, medial strut allograft, and bone autograft obtained with RIA system, together with a varus malalignment correction, leads to a high percentage of bone healing, with a low incidence of complications and good clinical outcome.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consolidação da Fratura / Fraturas do Quadril Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: BMC Musculoskelet Disord Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consolidação da Fratura / Fraturas do Quadril Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: BMC Musculoskelet Disord Ano de publicação: 2022 Tipo de documento: Article