Strain-based discoordination imaging during exercise in heart failure with reduced ejection fraction: Feasibility and reproducibility.
Fixsen, Louis S; Wouters, Philippe C; Lopata, Richard G P; Kemps, Hareld M C.
Afiliação
  • Fixsen LS; Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, The Netherlands. l.s.fixsen@tue.nl.
  • Wouters PC; Department of Cardiology, University Medical Centre Utrecht, Utrecht, The Netherlands.
  • Lopata RGP; Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB, Eindhoven, The Netherlands.
  • Kemps HMC; Department of Cardiology, Maxima Medical Centre, Veldhoven, The Netherlands.
BMC Cardiovasc Disord ; 22(1): 127, 2022 03 25.
Article em En | MEDLINE | ID: mdl-35337295
ABSTRACT

PURPOSE:

Various parameters of mechanical dyssynchrony have been proposed to improve patient selection criteria for cardiac resynchronization therapy, but sensitivity and specificity are lacking. However, echocardiographic parameters are consistently investigated at rest, whereas heart failure (HF) symptoms predominately manifest during submaximal exertion. Although strain-based predictors of response are promising, feasibility and reproducibility during exercise has yet to be demonstrated.

METHODS:

Speckle-tracking echocardiography was performed in patients with HF at two separate visits. Echocardiography was performed at rest, during various exercise intensity levels, and during recovery from exercise. Systolic rebound stretch of the septum (SRSsept), systolic shortening, and septal discoordination index (SDI) were calculated.

RESULTS:

Echocardiography was feasible in about 70-80% of all examinations performed during exercise. Of these acquired views, 84% of the cine-loops were suitable for analysis of strain-based mechanical dyssynchrony. Test-retest variability and intra- and inter-operator reproducibility at 30% and 60% of the ventilatory threshold (VT) were about 2.5%. SDI improved in the majority of patients at 30% and 60% of the VT, with moderate to good agreement between both intensity levels.

CONCLUSION:

Although various challenges remain, exercise echocardiography with strain analysis appears to be feasible in the majority of patients with dyssynchronous heart failure. Inter- and intra-observer agreement of SRSsept and SDI up to 60% of the VT were comparable to resting values. During exercise, the extent of SDI was variable, suggesting a heterogeneous response to exercise. Further research is warranted to establish its clinical significance.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: BMC Cardiovasc Disord Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: BMC Cardiovasc Disord Ano de publicação: 2022 Tipo de documento: Article