Your browser doesn't support javascript.
loading
A validated method for the rapid quantification of melatonin in over-the-counter hypnotics by the atmospheric pressure solid analysis probe (ASAP).
Moser, Daniel; Hussain, Shah; Rainer, Matthias; Jakschitz, Thomas; Bonn, Günther K.
Afiliação
  • Moser D; ADSI-Austrian Drug Screening Institute GmbH, Innrain 66a, 6020 Innsbruck, Austria.
  • Hussain S; Institute of Analytical Chemistry and Radiochemistry, University of Innsbruck, Innrain 80/82, 6020 Innsbruck, Austria. m.rainer@uibk.ac.at.
  • Rainer M; ADSI-Austrian Drug Screening Institute GmbH, Innrain 66a, 6020 Innsbruck, Austria.
  • Jakschitz T; Institute of Analytical Chemistry and Radiochemistry, University of Innsbruck, Innrain 80/82, 6020 Innsbruck, Austria. m.rainer@uibk.ac.at.
  • Bonn GK; ADSI-Austrian Drug Screening Institute GmbH, Innrain 66a, 6020 Innsbruck, Austria.
Anal Methods ; 14(16): 1603-1610, 2022 04 21.
Article em En | MEDLINE | ID: mdl-35383798
ABSTRACT
Melatonin is a hormone that regulates the biological day and night cycle. It is mainly produced by the pineal gland during the night. People suffering from insomnia use it as a soporific drug. The aim of this study was to develop a method for the rapid quantification of melatonin in hypnotics. For that purpose, atmospheric pressure solid analysis probe-assisted mass spectrometry was applied, where no chromatographic separation is needed. Thereby, one single analysis takes less than 1 min. Reference measurements were performed with ultra-high-performance liquid chromatography coupled with a quadrupole-time-of-flight mass spectrometer. Both methods were validated and real sample extracts were tested. The coefficients of determination were above 0.97 for both methods. The limits of detection and quantification were below 1 mg kg-1. Both methods gave comparable results. Moreover, the content of melatonin differed from the specified value in many samples. The highest and lowest observed deviations were 78% and 1%, respectively.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Melatonina Limite: Humans Idioma: En Revista: Anal Methods Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Melatonina Limite: Humans Idioma: En Revista: Anal Methods Ano de publicação: 2022 Tipo de documento: Article