Disc battery ingestion in paediatric age.
Quitadamo, Paolo; Caruso, Flora; Del Monaco, Casimiro; Fiori Nastro, Francesca; Verde, Alessandra; Dolce, Pasquale; Caldore, Mariano; Bucci, Cristina.
Afiliação
  • Quitadamo P; Digestive Endoscopy and Gastroenterological Emergency Unit, Santobono-Pausilipon Children's Hospital, Naples, Italy.
  • Caruso F; Digestive Endoscopy and Gastroenterological Emergency Unit, Santobono-Pausilipon Children's Hospital, Naples, Italy.
  • Del Monaco C; Paediatric Surgery Unit, Santobono-Pausilipon Children's Hospital, Naples, Italy.
  • Fiori Nastro F; Department of Translational Medical Science, Section of Pediatrics, University "Federico II", Naples, Italy.
  • Verde A; Department of Translational Medical Science, Section of Pediatrics, University "Federico II", Naples, Italy.
  • Dolce P; Department of Public Health, University of Naples Federico II, Naples, Italy.
  • Caldore M; Digestive Endoscopy and Gastroenterological Emergency Unit, Santobono-Pausilipon Children's Hospital, Naples, Italy.
  • Bucci C; Digestive Endoscopy and Gastroenterological Emergency Unit, Santobono-Pausilipon Children's Hospital, Naples, Italy.
Acta Paediatr ; 111(8): 1615-1620, 2022 08.
Article em En | MEDLINE | ID: mdl-35416315
ABSTRACT

AIM:

The aim of the present study was to analyse clinical data of children referred for disc battery ingestion in order to assess short- and long-term reported injuries and to identify outcome predictors and trends, define the urgency of intervention and refine treatment guidelines.

METHODS:

The records of all children admitted to Santobono-Pausilipon Children's Hospital, Naples, Italy for disc battery ingestion from January 2016 to December 2020 were retrospectively reviewed. Odds ratio were computed to assess the association between the different study variables and the rate of complications.

RESULTS:

We enrolled 118 children. Mild to major complications related to the ingested disc batteries were reported in 12/118 (10.2%) patients. Disc battery oesophageal retention, disc battery diameter >20 mm, together with age below 1 year and symptomatic presentation were the most important factors associated with poor clinical outcome.

CONCLUSION:

Our data confirm that ingested disc batteries are a serious health hazard and require a timely and qualified medical evaluation. We have identified three predictors of outcome severity oesophageal retention, large-diameter cells and symptom onset. Disc batteries lodged beyond the oesophagus appear substantially harmless and we may support a more conservative approach.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fontes de Energia Elétrica / Corpos Estranhos Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Child / Child, preschool / Female / Humans / Infant / Male País/Região como assunto: Europa Idioma: En Revista: Acta Paediatr Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fontes de Energia Elétrica / Corpos Estranhos Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Child / Child, preschool / Female / Humans / Infant / Male País/Região como assunto: Europa Idioma: En Revista: Acta Paediatr Ano de publicação: 2022 Tipo de documento: Article