Terbium doped LiLuF4 nanocrystal scintillator-based flexible composite film for high resolution X-ray imaging.
Lu, Hao; Xu, Xieming; Feng, Guiqing; Sun, Baoping; Wang, Shuaihua; Wu, Shaofan.
Afiliação
  • Lu H; College of Chemistry and Materials Science, Fujian Normal University Fuzhou 350117 China.
  • Xu X; Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences Fuzhou 350002 P. R. China shwang@fjirsm.ac.cn.
  • Feng G; Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences Fuzhou 350002 P. R. China shwang@fjirsm.ac.cn.
  • Sun B; University of Chinese Academy of Sciences Beijing 100049 P. R. China.
  • Wang S; College of Chemistry and Materials Science, Fujian Normal University Fuzhou 350117 China.
  • Wu S; Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences Fuzhou 350002 P. R. China shwang@fjirsm.ac.cn.
RSC Adv ; 12(8): 4615-4623, 2022 Feb 03.
Article em En | MEDLINE | ID: mdl-35425475
ABSTRACT
Radiographic screens are widely used in high energy physics, national defense, aviation, radiodynamic therapy and medical imaging due to their scintillation materials that can transform high-energy particles or rays into ultraviolet (UV) visible light or other signals. In recent years, lanthanide doped fluoride nanocrystals (NCs) have attracted much attention due to their excellent optical properties and stability. In this work, multiple lanthanide-doped LiLuF4 nanocrystal scintillation materials were synthesized by thermal decomposition. Among them, Tb-doped LiLuF4 nanocrystals have high X-ray sensitivity and low detection limit (36.31 nGy s-1), which is much lower than the requirement of medical imaging dose rate. After the irradiation of 42.29 mGy s-1 X-ray for 1 hour, the intensity of radioluminescence basically remained unchanged. Based on the good properties of our nanocrystals, we further prepared the flexible film of nanocomposites with epoxy resin. This kind of uniform, large area, high loaded flexible film exhibits excellent performance in X-ray imaging with a spatial resolution greater than 20 line pairs per millimeter (LP/mm).