Your browser doesn't support javascript.
loading
Online SPE UPLC-MS/MS method for the simultaneous determination of 33 psychoactive drugs from swab-collected human oral fluid samples.
Mercier, Benoit; Scala-Bertola, Julien; Pape, Elise; Kolodziej, Allan; Gibaja, Valérie; Bisch, Michael; Jouzeau, Jean-Yves; Gambier, Nicolas.
Afiliação
  • Mercier B; Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France.
  • Scala-Bertola J; Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France.
  • Pape E; Université de Lorraine, CNRS, IMoPA, 54505, Vandœuvre, France.
  • Kolodziej A; Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France.
  • Gibaja V; Université de Lorraine, CNRS, IMoPA, 54505, Vandœuvre, France.
  • Bisch M; Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France.
  • Jouzeau JY; Département de Pharmacologie Clinique et Toxicologie, Université de Lorraine, CHRU-Nancy, 54500, Vandœuvre, France.
  • Gambier N; Centre Psychothérapique de Nancy, Département d'Addictologie, Pôle Hospitalo-Universitaire du Grand Nancy, 54520, Laxou, France.
Anal Bioanal Chem ; 414(14): 4203-4215, 2022 Jun.
Article em En | MEDLINE | ID: mdl-35451622
ABSTRACT
Oral fluid is easy and safe to collect and allows the detection of drugs of abuse after local exposure by oral, smoked, and/or inhaled intake, or systemic exposure. A routine online solid-phase extraction UPLC-MS/MS method was developed for the simultaneous determination of 33 psychoactive drugs in oral fluid. The selected drugs were fourteen fentanyl analogs and nineteen other abused psychoactive compounds, including classical narcotics, which were analyzed in a run of 10 min. Limits of detection and of quantification ranged from 0.02 to 1 ng/mL and from 0.02 to 5 ng/mL depending on the analyte, respectively. Matrix effect was in the range - 17 to + 15.7% for all analytes having a deuterated analog. Accuracy ranged from 82.7 to 113.4% and precision CV was at worst of 18.6%. Carryover was below 0.8% for all analytes. Recovery from FLOQSwabs™ showed high variability between analytes with THC, D2FF, 4-ANPP, ocfentanil, and valerylfentanyl being recovered below 40%. A stability study performed over 2 weeks on collecting devices loaded with artificial oral fluid showed huge variation between analytes with morphine, BZE, and norfentanyl being the more stable. Storage at 4 °C allowed drug detection for 1 week except for THC and remifentanil. The method was successfully applied to the detection of abused psychoactive compounds in oral fluid samples from 6 patients admitted to an addiction department.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 Base de dados: MEDLINE Assunto principal: Dronabinol / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 Base de dados: MEDLINE Assunto principal: Dronabinol / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2022 Tipo de documento: Article