Validation of the RCOphth and UKEGS glaucoma risk stratification tool 'GLAUC-STRAT-fast'.
Konstantakopoulou, Evgenia; Kastner, Alan; Gazzard, Gus; Jayaram, Hari.
Afiliação
  • Konstantakopoulou E; Glaucoma Service, Moorfields Eye Hospital NHS Foundation Trust, London, UK.
  • Kastner A; Optics & Optometry, University of West Attica, Egaleo, Greece.
  • Gazzard G; Glaucoma Service, Moorfields Eye Hospital NHS Foundation Trust, London, UK.
  • Jayaram H; Pontificia Universidad Católica de Chile, Santiago, Chile.
Br J Ophthalmol ; 107(9): 1258-1263, 2023 09.
Article em En | MEDLINE | ID: mdl-35534178
ABSTRACT
BACKGROUND/

AIMS:

The aim of this study was to validate the Glaucoma Risk Stratification Tool (GLAUC-STRAT-fast) currently recommended by the Royal College of Ophthalmologists for the risk stratification of patients with glaucoma in the UK National Health Service Hospital Eye Service.

METHODS:

GLAUC-STRAT fast was applied to the LiGHT trial participants by risk-stratifying the worse eye of each patient at baseline and after 3 years of treatment. Metrics of disease severity or treatment intensity used for the validation were increased number of monitoring visits or treatment escalations; needing a trabeculectomy; a reduction of >2 dB in visual field mean deviation (VF MD) during the monitoring period; identification of rapid VF loss on total (TD) and/or pattern deviation (PD). The proportion of eyes within each baseline stratum for each of the above markers was compared against the other strata, using a χ2 test for proportions.

RESULTS:

There was an association between the baseline stratification and the number of treatment escalations needed to maintain the eye-specific target intraocular pressure (p=0.001), the number of visits needed throughout the 3-year follow-up period (p=0.001), the need for trabeculectomy (p<0.001) and absolute loss of MD over the course of the monitoring period (p<0.001). The rate of VF progression was not associated with baseline risk stratification for TD or PD progression (p≥0.007, with Bonferroni correction).

CONCLUSION:

The GLAUC-STRAT fast tool is a useful tool for risk stratifying eyes with ocular hypertension or open angle glaucoma. Further research is needed to confirm and validate its applicability to more advanced glaucomas and generalisability to clinical use. TRIAL REGISTRATION NUMBER The LiGHT trial is registered at controlled-trials.com (ISRCTN32038223).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Glaucoma de Ângulo Aberto Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Br J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Glaucoma de Ângulo Aberto Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Br J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article