Your browser doesn't support javascript.
loading
Treatment of distal radius fractures using a cemented K-wire frame.
Meng, Hongyu; Xu, Bin; Xu, Yi; Niu, Haiyun; Liu, Ning; Sun, Donglei.
Afiliação
  • Meng H; Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei, China.
  • Xu B; Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, 050000, Hebei, China.
  • Xu Y; Orthopaedic Research Institution of Hebei Province, Shijiazhuang, 050000, Hebei, China.
  • Niu H; Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei, China.
  • Liu N; Key Laboratory of Biomechanics of Hebei Province, Shijiazhuang, 050000, Hebei, China.
  • Sun D; Orthopaedic Research Institution of Hebei Province, Shijiazhuang, 050000, Hebei, China.
BMC Musculoskelet Disord ; 23(1): 591, 2022 Jun 20.
Article em En | MEDLINE | ID: mdl-35725465
BACKGROUND: This retrospective study included an alternative treatment for types A2, A3, and B1 distal radius fractures using percutaneous fixation with a cemented K-wire frame. METHODS: From January 2017 to January 2020, 78 patients with distal radius fractures were treated with percutaneous internal fixation using a cemented K-wire frame. There were 47 male patients and 31 female patients. The fractures were classified into types A2 (n = 10), A3 (n = 46), and B1 (n = 22). X-rays were taken immediately after surgery and after the bone had healed. Wrist function was assessed using the Mayo Wrist Score (90-100, excellent; 80-90, good; 60-80, satisfactory; < 60, poor). Patient satisfaction was assessed using the 10-cm visual analog scale. RESULTS: Neither fixation failure nor K-wire migration was found (P > 0.05). Osteomyelitis was not observed in this series. All patients achieved bone healing after a mean of 4.5 weeks (range, 4 to 8 weeks). Follow-up lasted a mean of 27 months (range, 24 to 33 months). The mean score of wrist function was 97 (range, 91 to 100). Among them, 66 results were excellent and 12 results were good. The mean patient satisfaction was 10 cm (range, 8 to 10 cm). CONCLUSIONS: Percutaneous fixation with cemented K-wire frame is a safe and preferred choice for the treatment of types A2, A3, and B1 distal radius fractures. The frame provides support to prevent wire migration. The fixation technique is a minimally invasive procedure that is easy to perform. LEVEL OF EVIDENCE: Therapeutic study, Level IVa.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Rádio Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Female / Humans / Male Idioma: En Revista: BMC Musculoskelet Disord Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Rádio Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Female / Humans / Male Idioma: En Revista: BMC Musculoskelet Disord Ano de publicação: 2022 Tipo de documento: Article