Your browser doesn't support javascript.
loading
Flexible Non-contact Electrodes for Wearable Biosensors System on Electrocardiogram Monitoring in Motion.
Wang, Xin; Liu, Shuting; Zhu, Mingxing; He, Yuchao; Wei, Zhilong; Wang, Yingying; Xu, Yangjie; Pan, Hongguang; Huang, Weimin; Chen, Shixiong; Li, Guanglin.
Afiliação
  • Wang X; CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Liu S; Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China.
  • Zhu M; Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • He Y; Department of Informatics, Technical University of Munich, Munich, Germany.
  • Wei Z; CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Wang Y; School of Electronics and Information Engineering, Harbin Institute of Technology, Shenzhen, China.
  • Xu Y; CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Pan H; Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Huang W; CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Chen S; Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
  • Li G; CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
Front Neurosci ; 16: 900146, 2022.
Article em En | MEDLINE | ID: mdl-35747208
ABSTRACT
Electrocardiogram (ECG) is a critical physiological indicator that contains abundant information about human heart activities. However, it is a kind of weak low-frequency signal, which is easy to be interfered by various noises. Therefore, wearable biosensors (WBS) technique is introduced to overcome this challenge. A flexible non-contact electrode is proposed for wearable biosensors (WBS) system, which is made up of flexible printed circuits materials, and can monitor the ECG signals during exercise for a long time. It uses the principle of capacitive coupling to obtain high-quality signals, and reduces the impact of external noise through active shielding; The results showed that the proposed non-contact electrode was equivalent to a medical wet electrode. The correlation coefficient was as high as 99.70 ± 0.30% when the subject was resting, while it was as high as 97.53 ± 1.80% during exercise. High-quality ECG could still be collected at subjects walking at 7 km/h. This study suggested that the proposed flexible non-contact electrode would be a potential tool for wearable biosensors for medical application on long-term monitoring of patients' health and provide athletes with physiological signal measurements.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Neurosci Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Neurosci Ano de publicação: 2022 Tipo de documento: Article