Your browser doesn't support javascript.
loading
Quantifying osteosynthesis plate prominence - mathematical definitions and case study on a clavicle plate.
Zenker, Martin; Theodorou, Evangelos; Andermatt, Daniel; Winkler, Ralf; Hoyen, Harry A; Jaeger, Martin; Jiang, Chunyan; Lambert, Simon; Nijs, Stefaan; Fontana, Arabella D.
Afiliação
  • Zenker M; R&D Department, DePuy Synthes, Zuchwil, Switzerland.
  • Theodorou E; R&D Department, DePuy Synthes, Zuchwil, Switzerland.
  • Andermatt D; R&D Department, DePuy Synthes, Zuchwil, Switzerland.
  • Winkler R; Innomedic GmbH, DePuy Synthes, Philippsburg-Rheinsheim, Germany.
  • Hoyen HA; Department of Orthopaedic Surgery, MetroHealth Medical Center, Case Western Reserve University, Cleveland, OH, USA.
  • Jaeger M; Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Freiburg, Freiburg, Germany.
  • Jiang C; Shoulder Service, School of Medicine, Beijing Jishuitan Hospital, Peking University, Peking, China.
  • Lambert S; Department of Trauma and Orthopedic Surgery, University College London Hospital NHS Foundation Trust, London, UK.
  • Nijs S; Department of Trauma Surgery, University Hospitals Leuven, Leuven, Belgium.
  • Fontana AD; R&D Department, DePuy Synthes, Zuchwil, Switzerland.
Comput Methods Biomech Biomed Engin ; 26(8): 917-926, 2023 Jun.
Article em En | MEDLINE | ID: mdl-35833691
Hardware prominence remains a clinical challenge in focus for implant design in subcutaneous plate applications. Existing evaluation of hardware prominence relies on plate-to-bone distance at a single point or on average. A reproducible measure for plate prominence remains undefined. This study mathematically defines the plate prominence linked to the cross-sectional area change due to the plate presence on the bone. Two anatomical plate designs were fitted to 100 clavicles, and afterwards plate prominence parameters were evaluated and compared. This methodology enables the quantification of hardware prominence for different plate designs to inform the development of implants targeting low prominence.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas Ósseas Limite: Humans Idioma: En Revista: Comput Methods Biomech Biomed Engin Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas Ósseas Limite: Humans Idioma: En Revista: Comput Methods Biomech Biomed Engin Ano de publicação: 2023 Tipo de documento: Article