Your browser doesn't support javascript.
loading
Comparing Mycobacterium tuberculosis RNA Accuracy in Various Respiratory Specimens for the Rapid Diagnosis of Pulmonary Tuberculosis.
Qiu, Xiaowei; Zheng, Sipei; Yang, Jun; Yu, Guocan; Ye, Yiming.
Afiliação
  • Qiu X; Department of Radiology, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China.
  • Zheng S; The Second School of Medicine, Wenzhou Medical University, Wenzhou, People's Republic of China.
  • Yang J; Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China.
  • Yu G; Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China.
  • Ye Y; Clinical Medical Examination Laboratory Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China.
Infect Drug Resist ; 15: 4195-4202, 2022.
Article em En | MEDLINE | ID: mdl-35946035
ABSTRACT

Objective:

To evaluate the rapid diagnostic accuracy of Mycobacterium tuberculosis RNA (TB-RNA) for pulmonary tuberculosis (PTB) in a large patient sample and to evaluate the difference in TB-RNA diagnostic accuracy in various respiratory specimens.

Methods:

Patient medical records were retrospectively reviewed to determine the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the curve (AUC) of the acid-fast bacillus (AFB) smear and TB-RNA to evaluate their diagnostic accuracy against final clinical diagnosis.

Results:

Of the 2336 patients ultimately included, 1123 provided 1 sputum specimen each and 1213 provided 1 bronchoalveolar lavage fluid (BALF) specimen each. The overall sensitivity, specificity, PPV, NPV, and AUC of the AFB smear were 36.2%, 86.4%, 90.6%, 27.3%, and 0.61, respectively. The overall sensitivity, specificity, PPV, NPV, and AUC of TB-RNA for the rapid detection of PTB were 57.4%, 99.4%, 99.7%, 39.3%, and 0.78, respectively. When sputum and BALF specimens were used for AFB smear testing, the sensitivity, specificity, PPV, NPV, and AUC of the AFB smear were 44.5%, 81.5%, 87.5%, 33.5%, and 0.63; and 29.2%, 92.7%, 94.8%, 22.5%, and 0.61, respectively. The sensitivity, specificity, PPV, NPV, and AUC of TB-RNA for the rapid detection of PTB using sputum were 49.6%, 99.3%, 99.5%, 40.4%, and 0.74, respectively; whereas those of TB-RNA determined using BALF were 63.9%, 99.5%, 99.8%, 38.0%, and 0.82, respectively.

Conclusion:

The diagnostic accuracy of TB-RNA for PTB was moderate and considerably better than that of the AFB smear. The diagnostic accuracy of TB-RNA for various respiratory specimens differed; the diagnostic accuracy of TB-RNA for BALF specimens was substantially better than that for sputum samples, and BALF specimens were more suitable for TB-RNA.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Infect Drug Resist Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Infect Drug Resist Ano de publicação: 2022 Tipo de documento: Article