Your browser doesn't support javascript.
loading
Comparison of spin-echo echo-planar imaging magnetic resonance elastography with gradient-recalled echo magnetic resonance elastography and their correlation with transient elastography.
Yoon, Jin Woo; Lee, Eun Sun; Park, Hyun Jeong; Park, Sung Bin; Cho, Young Youn; Kannengiesser, Stephan; Hur, Joonho.
Afiliação
  • Yoon JW; Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102, Heukseok-ro, Dongjak-gu, Republic of Korea.
  • Lee ES; Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102, Heukseok-ro, Dongjak-gu, Republic of Korea.
  • Park HJ; Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102, Heukseok-ro, Dongjak-gu, Republic of Korea.
  • Park SB; Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102, Heukseok-ro, Dongjak-gu, Republic of Korea.
  • Cho YY; Department of Internal Medicine, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102, Heukseok-ro, Dongjak-gu, Republic of Korea.
  • Kannengiesser S; Siemens Healthcare GmbH, Erlangen, Germany.
  • Hur J; Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102, Heukseok-ro, Dongjak-gu, Republic of Korea.
Diagn Interv Radiol ; 28(4): 294-300, 2022 Jul.
Article em En | MEDLINE | ID: mdl-35950274
ABSTRACT
PURPOSE This study aimed to assess the agreement between liver stiffness (LS) values obtained by the gradient-recalled echo (GRE) magnetic resonance elastography (MRE) and spin-echo echo-planar imaging (SE-EPI) MRE with those of transient elastography (TE), respectively. METHODS We retrospectively included 48 participants who underwent liver MRE with both GRE and SE-EPI sequences in the same session and also TE within 1 year. We obtained LS values for MRE by drawing free-hand region of interest, and TE was performed using a FibroScan device. We assessed the relationship between the mean LS values obtained by each MRE sequence and TE using the correlation coefficients and Bland-Altman plots, respectively. We also compared LS values and technical failure rates of measured values from MRE between SE-EPI and GRE sequences using the paired t-test and McNemar's test. The MRE failure was defined as the absence of pixel value with a confidence index above 95%. RESULTS The LS values from SE-EPI and GRE sequences strongly correlated with those from TE (GRE; r = 0.73, P < .001 vs. SE-EPI; r = 0.79, P < .001). In addition, the LS values from the 2 MRE sequences showed excellent relationship (intraclass correlation coefficient, 0.94 [0.89-0.97], P < .001). The LS values from SE-EPI and GRE MRE were not significantly different (4.14 kPa vs. 3.88 kPa, P = .19). Furthermore, the technical success rate of SE-EPI MRE was superior to that of GRE (100% vs. 83.8%, P = .031). CONCLUSION The measured LS values obtained using TE correlated strongly with those obtained using GRE and SE-EPI MRE techniques, even though SE-EPI-MRE resulted a higher technical success rate than GRE-MRE. Therefore, we believe that TE, GRE, and SE-EPI MR elastography techniques may complement each other according to the appropriate individual situation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: Diagn Interv Radiol Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: Diagn Interv Radiol Ano de publicação: 2022 Tipo de documento: Article