Your browser doesn't support javascript.
loading
Assessment of the relationship between rectus femoris cross-sectional area and knee extension strength in the prosthesis users with transtibial amputation: A case-control study.
Atalay, Kardelen Gencer; Kenis Coskun, Özge; Giray, Esra; Gündüz, Osman Hakan; Yagci, Ilker.
Afiliação
  • Atalay KG; Department of Physical Medicine and Rehabilitation, Marmara University Faculty of Medicine, Istanbul, Türkiye.
  • Kenis Coskun Ö; Department of Physical Medicine and Rehabilitation, Marmara University Faculty of Medicine, Istanbul, Türkiye.
  • Giray E; Department of Physical Medicine and Rehabilitation, Marmara University Faculty of Medicine, Istanbul, Türkiye.
  • Gündüz OH; Department of Physical Medicine and Rehabilitation, Marmara University Faculty of Medicine, Istanbul, Türkiye.
  • Yagci I; Department of Physical Medicine and Rehabilitation, Marmara University Faculty of Medicine, Istanbul, Türkiye.
Turk J Phys Med Rehabil ; 68(2): 222-230, 2022 Jun.
Article em En | MEDLINE | ID: mdl-35989968
ABSTRACT

Objectives:

This study aims to investigate cross-sectional area of the amputated-limb rectus femoris compared to the intact-limb and controls and to determine its correlation with functional strength and walking tests in prosthesis users with transtibial amputation. Patients and

methods:

Between October 2018 and April 2019, a total of 14 prosthesis users (12 males, 2 females; mean age 47.1±16.2 years; range, 26 to 73 years) who met the inclusion criteria, and 14 age-, sex-, and dominancy-matched able-bodied controls (12 males, 2 females; mean age 47.1±16.2 years; range, 26 to 73 years) were included in this case-control study. Cross-sectional area of rectus femoris (CSA-RF) was evaluated bilaterally by two independent examiners. Knee extension strength was measured bilaterally by using a handheld dynamometer. Functional strength and walking were assessed by Step-Up-Over and Walk-Across tests of the NeuroCom Balance Master® device.

Results:

The CSA-RF was found to be reduced in amputated-limb compared to the intact-limb and able-bodied controls (p<0.01). In the prosthesis users, the cross-sectional area difference between both limbs rectus femoris muscles was shown to be correlated with actual and functional knee extension strength, step length, and walking speed (p<0.05). Intra- and inter-observer reliability of CSA-RF on both sides were found to be good to excellent (intraclass correlation coefficient 0.856-0.936).

Conclusion:

Ultrasonographic measurement of CSA-RF is a valid and reliable tool to assess the functional strength and walking in the prosthesis users with unilateral transtibial amputation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prevalence_studies Idioma: En Revista: Turk J Phys Med Rehabil Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prevalence_studies Idioma: En Revista: Turk J Phys Med Rehabil Ano de publicação: 2022 Tipo de documento: Article