Your browser doesn't support javascript.
loading
Evaluation of a Novel Precordial Lead System for the Electrocardiographic Diagnosis of Right Ventricular Enlargement in Dogs.
Grosso, Giovanni; Vezzosi, Tommaso; Pergamo, Cesara Sofia; Bini, Martina; Patata, Valentina; Domenech, Oriol; Tognetti, Rosalba.
Afiliação
  • Grosso G; Department of Veterinary Sciences, University of Pisa, Via Livornese, San Piero a Grado, 56122 Pisa, Italy.
  • Vezzosi T; Department of Veterinary Sciences, University of Pisa, Via Livornese, San Piero a Grado, 56122 Pisa, Italy.
  • Pergamo CS; Department of Veterinary Sciences, University of Pisa, Via Livornese, San Piero a Grado, 56122 Pisa, Italy.
  • Bini M; Anicura Istituto Veterinario Novara, Strada Provinciale 9, Granozzo con Monticello, 28060 Novara, Italy.
  • Patata V; Anicura Istituto Veterinario Novara, Strada Provinciale 9, Granozzo con Monticello, 28060 Novara, Italy.
  • Domenech O; Anicura Istituto Veterinario Novara, Strada Provinciale 9, Granozzo con Monticello, 28060 Novara, Italy.
  • Tognetti R; Department of Veterinary Sciences, University of Pisa, Via Livornese, San Piero a Grado, 56122 Pisa, Italy.
Vet Sci ; 9(8)2022 Jul 30.
Article em En | MEDLINE | ID: mdl-36006313
The purpose of this study was to evaluate the reliability of precordial leads for the detection of right ventricular enlargement (RVE) in dogs. This was a prospective observational study. The RVE was defined by echocardiography. The amplitude (mV) of the Q, R, and S waves, the R/S ratio, and the mean electrical axis (MEA) of the QRS complex were assessed on the 12-lead ECG. The ROC curve and the Youden index yielded the best cutoffs for RVE detection. An area under the curve (AUC) > 0.7 defined suitable diagnostic accuracy. A total of 84 dogs, 27 with RVE and 57 healthy controls, were enrolled. Q wave amplitude in aVR (cutoff > 0.10 mV; AUC = 0.727), R/S ratio in V4 (cutoff < 1.15; AUC = 0.842), R/S ratio in V5 (cutoff < 1.95; AUC = 0.839) and S wave amplitude in V6 (cutoff > 0.70 mV; AUC = 0.703) showed suitable diagnostic accuracy in detecting RVE. Among dogs with RVE, only 9/27 (33%) presented a right shift of MEA. Differently, 19/27 (70%) showed at least one of the identified precordial lead criteria. Assessment of the R/S ratio in V4 and V5 and S wave amplitude in V6 increases the diagnostic accuracy of ECG in distinguishing between dogs with RVE and healthy dogs.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Idioma: En Revista: Vet Sci Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Idioma: En Revista: Vet Sci Ano de publicação: 2022 Tipo de documento: Article