Your browser doesn't support javascript.
loading
Highly Sensitive Electrochemical Detection of Azithromycin with Graphene-Modified Electrode.
Pogacean, Florina; Varodi, Codruta; Magerusan, Lidia; Stefan-van Staden, Raluca-Ioana; Pruneanu, Stela.
Afiliação
  • Pogacean F; National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103, Donat Street, 400293 Cluj-Napoca, Romania.
  • Varodi C; National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103, Donat Street, 400293 Cluj-Napoca, Romania.
  • Magerusan L; National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103, Donat Street, 400293 Cluj-Napoca, Romania.
  • Stefan-van Staden RI; Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021 Bucharest, Romania.
  • Pruneanu S; Faculty of Applied Chemistry and Material Science, Politehnica University of Bucharest, 060042 Bucharest, Romania.
Sensors (Basel) ; 22(16)2022 Aug 18.
Article em En | MEDLINE | ID: mdl-36015941
ABSTRACT
An electrochemical cell containing two graphite rods was filled with the appropriate electrolyte (0.2 M ammonia + 0.2 M ammonium sulphate) and connected to the exfoliation system to synthesize graphene (EGr). A bias of 7 V was applied between the anode and cathode for 3 h. After synthesis, the morphology and structure of the sample was characterized by SEM, XRD, and FTIR techniques. The material was deposited onto the surface of a glassy carbon (GC) electrode (EGr/GC) and employed for the electrochemical detection of azithromycin (AZT). The DPV signals recorded in pH 5 acetate containing 6 × 10-5 M AZT revealed significant differences between the GC and EGr/GC electrodes. For EGr/GC, the oxidation peak was higher and appeared at lower potential (+1.12 V) compared with that of bare GC (+1.35 V). The linear range for AZT obtained with the EGr/GC electrode was very wide, 10-8-10-5 M, the sensitivity was 0.68 A/M, and the detection limit was 3.03 × 10-9 M. It is important to mention that the sensitivity of EGr/GC was three times higher than that of bare GC (0.23 A/M), proving the advantages of using graphene-modified electrodes in the electrochemical detection of AZT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article