Your browser doesn't support javascript.
loading
Comparison of Retention and Seating of Implant-Supported Hard and Soft Metal Copings.
Ghodsi, Safoura; Fayyazi, Anahita; Ghiasi, Maryam; Rohanian, Ahmad; Alikhasi, Marzieh.
Afiliação
  • Ghodsi S; Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • Fayyazi A; Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
  • Ghiasi M; Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Rohanian A; Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • Alikhasi M; Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Front Dent ; 17: 26, 2020.
Article em En | MEDLINE | ID: mdl-36042806
ABSTRACT

Objectives:

Implant-supported restorations are generally used for the replacement of the lost teeth. Stability against masticatory forces and proper retention are critical for optimal durability of restorations. The aim of this experimental study was to compare the retention of cobalt-chromium (Co-Cr) copings made by different techniques. Materials and

Methods:

Twenty-four solid abutment analogs were mounted and scanned with a desktop scanner. They were divided into two groups (n=12) and received metal copings fabricated by either soft or hard Co-Cr alloy. Soft Ceramill Sintron Co-Cr patterns were milled and sintered. Hard Co-Cr blocks were milled in a milling machine. The copings were sandblasted, polished, adjusted, and placed on the respective abutments. The frequency of adjustments was recorded for each abutment. The copings were cemented with zinc phosphate cement and underwent tensile test by a universal testing machine. The Mann-Whitney test and t-test were used to compare the two groups (α=0.05).

Results:

There was no significant difference in retention of copings between the experimental groups. The mean retentive force was 559.58±115.66 N and 557.13 ±130.48 N for the soft and hard metal groups, respectively (P=0.96). Considering the non-normal distribution of adjustment frequency data, the Mann-Whitney test showed that the frequency of adjustments was significantly higher in the hard metal group than the soft metal group (9.5 versus 0.1667; P<0.001).

Conclusion:

Although hard metal copings required more adjustments, retention of soft and hard Co-Cr copings was not significantly different.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Dent Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Dent Ano de publicação: 2020 Tipo de documento: Article