Your browser doesn't support javascript.
loading
A flexible implantable microelectrode array for recording electrocorticography signals from rodents.
Chatterjee, Suman; Sakorikar, Tushar; Bs, Arjun; Joshi, Rathin K; Sikaria, Abhay; Jayachandra, Mahesh; V, Vikas; Pandya, Hardik J.
Afiliação
  • Chatterjee S; Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore, India.
  • Sakorikar T; Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore, India.
  • Bs A; Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore, India.
  • Joshi RK; Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore, India.
  • Sikaria A; Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bangalore, India.
  • Jayachandra M; Center for BioSystems Science and Engineering, Indian Institute of Science, Bangalore, India.
  • V V; Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bangalore, India.
  • Pandya HJ; Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore, India. hjpandya@iisc.ac.in.
Biomed Microdevices ; 24(4): 31, 2022 09 17.
Article em En | MEDLINE | ID: mdl-36138255
Electrocorticography signals, the intracranial recording of electrical signatures of the brain, are recorded by non-penetrating planar electrode arrays placed on the cortical surface. Flexible electrode arrays minimize the tissue damage upon implantation. This work shows the design and development of a 32-channel flexible microelectrode array to record electrocorticography signals from the rat's brain. The array was fabricated on a biocompatible flexible polyimide substrate. A titanium/gold layer was patterned as electrodes, and a thin polyimide layer was used for insulation. The fabricated microelectrode array was mounted on the exposed somatosensory cortex of the right hemisphere of a rat after craniotomy and incision of the dura. The signals were recorded using OpenBCI Cyton Daisy Biosensing Boards. The array faithfully recorded the baseline electrocorticography signals, the induced epileptic activities after applying a convulsant, and the recovered baseline signals after applying an antiepileptic drug. The signals recorded by such fabricated microelectrode array from anesthetized rats demonstrate its potential to monitor electrical signatures corresponding to epilepsy. Finally, the time-frequency analyses highlight the difference in spatiotemporal features of baseline and evoked epileptic discharges.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Eletrocorticografia Limite: Animals Idioma: En Revista: Biomed Microdevices Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Eletrocorticografia Limite: Animals Idioma: En Revista: Biomed Microdevices Ano de publicação: 2022 Tipo de documento: Article