Your browser doesn't support javascript.
loading
Engineered Electroactive Solutions for Electrochemical Detection of Tuberculosis-Associated Volatile Organic Biomarkers.
Willis, Christina N; Larson, Shaylee R; Andama, Alfred; Jaganath, Devan; Misra, Manoranjan; Cattamanchi, Adithya; Mohanty, Swomitra K.
Afiliação
  • Willis CN; Department of Chemical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.
  • Larson SR; Department of Chemical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.
  • Andama A; Department of Medicine and the Infectious Disease Research Collaboration, Makerere University College of Health Sciences, Kampala, Uganda.
  • Jaganath D; Division of Pediatric Infectious Diseases, the Division of Pulmonary and Critical Care Medicine, and the Center for Tuberculosis, University of California San Francisco, San Francisco, CA 94110, USA.
  • Misra M; Department of Chemical Engineering and the Department of Materials Science and Engineering, The University of Utah, Salt Lake City, UT 84112, USA.
  • Cattamanchi A; Division of Pulmonary and Critical Care Medicine, the Center for Tuberculosis, and the Center for Vulnerable Populations, University of California San Francisco, San Francisco, CA 94110, USA.
  • Mohanty SK; Department of Chemical Engineering and the Department of Materials Science and Engineering, The University of Utah, Salt Lake City, UT 84112, USA.
IEEE Sens J ; 22(4): 2984-2992, 2022 Feb 15.
Article em En | MEDLINE | ID: mdl-36157103
ABSTRACT
Rapid screening of tuberculosis by evaluation of associated volatile organic biomarkers in breath is a promising technology that is significantly faster and more convenient than traditional sputum culture tests. Methyl nicotinate (MN) and methyl p-anisate (MPA) have been isolated as potential biomarkers for mycobacterium tuberculosis and have been found in the breath of patients with active pulmonary tuberculosis. A novel approach to detection of these biomarkers in liquid droplets (e.g. from breath condensate) using inexpensive screen-printed electrodes is presented. Previous modelling studies suggest that these biomarkers complex with certain transition metals of particular valence state. This interaction can be exploited by mixing the biomarker sample into an electroactive solution (EAS) containing the functional metal ion and observing the change electrochemically. The study focuses on low biomarker concentrations, determined to be clinically relevant based on preliminary GC-MS studies of the levels found in patient breath. It was found that both the cyclic voltammogram and square wave voltammogram of copper(II) change significantly when as little as 0.1 mM MN is added to the solution, with analysis times of less than 2 min. Copper(II) exhibits three separate peaks during square wave voltammetry. The location and area of each peak are affected differently as the concentration of MN increases, suggesting a reaction with specific oxidation states of the metal. In this way, a "fingerprint" method can be used to identify biomarkers once their known interaction is established.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Risk_factors_studies Idioma: En Revista: IEEE Sens J Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Risk_factors_studies Idioma: En Revista: IEEE Sens J Ano de publicação: 2022 Tipo de documento: Article