Your browser doesn't support javascript.
loading
Integrating a Luminescent Porous Aromatic Framework into Indicator Papers for Facile, Rapid, and Selective Detection of Nitro Compounds.
Cui, Bo; Gao, Changyuan; Fan, Jiating; Liu, Jinni; Feng, Bin; Ruan, Xianghui; Yang, Yajie; Yuan, Ye; Chu, Kuo; Yan, Zhuojun; Xia, Lixin.
Afiliação
  • Cui B; College of Chemistry, Liaoning University, Shenyang 110036, China.
  • Gao C; School of Environmental Science, Liaoning University, Shenyang 110036, China.
  • Fan J; College of Chemistry, Liaoning University, Shenyang 110036, China.
  • Liu J; College of Chemistry, Liaoning University, Shenyang 110036, China.
  • Feng B; College of Chemistry, Liaoning University, Shenyang 110036, China.
  • Ruan X; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Faculty of Chemistry, Northeast Normal University, Changchun 130024, China.
  • Yang Y; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Faculty of Chemistry, Northeast Normal University, Changchun 130024, China.
  • Yuan Y; Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Faculty of Chemistry, Northeast Normal University, Changchun 130024, China.
  • Chu K; School of Environmental Science, Liaoning University, Shenyang 110036, China.
  • Yan Z; College of Chemistry, Liaoning University, Shenyang 110036, China.
  • Xia L; College of Chemistry, Liaoning University, Shenyang 110036, China.
Molecules ; 27(19)2022 Sep 22.
Article em En | MEDLINE | ID: mdl-36234789
Porous aromatic framework materials with high stability, sensitivity, and selectivity have great potential to provide new sensors for optoelectronic/fluorescent probe devices. In this work, a luminescent porous aromatic framework material (LNU-23) was synthesized via the palladium-catalyzed Suzuki cross-coupling reaction of tetrabromopyrene and 1,2-bisphenyldiborate pinacol ester. The resulting PAF solid exhibited strong fluorescence emission with a quantum yield of 18.31%, showing excellent light and heat stability. Because the lowest unoccupied molecular orbital (LUMO) of LNU-23 was higher than that of the nitro compounds, there was an energy transfer from the excited LNU-23 to the analyte, leading to the selective fluorescence quenching with a limit of detection (LOD) ≈ 1.47 × 10-5 M. After integrating the luminescent PAF powder on the paper by a simple dipping method, the indicator papers revealed a fast fluorescence response to gaseous nitrobenzene within 10 s, which shows great potential in outdoor fluorescence detection of nitro compounds.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Paládio / Nitrocompostos Tipo de estudo: Diagnostic_studies Idioma: En Revista: Molecules Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Paládio / Nitrocompostos Tipo de estudo: Diagnostic_studies Idioma: En Revista: Molecules Ano de publicação: 2022 Tipo de documento: Article