Your browser doesn't support javascript.
loading
Rapid and reliable triple-emissive detection of 2,6-dichloro-4-nitroaniline as a pesticide based on a high-nuclear Cd(II)-Sm(III) nanocluster.
Leng, Xilong; Yang, Xiaoping; Ma, Yanan; Wang, Chengri; Li, Hao; Zhang, Zhen; Yang, Keqin; Schipper, Desmond.
Afiliação
  • Leng X; College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou 325035, China. xpyang@wzu.edu.cn.
  • Yang X; College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou 325035, China. xpyang@wzu.edu.cn.
  • Ma Y; College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou 325035, China. xpyang@wzu.edu.cn.
  • Wang C; College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou 325035, China. xpyang@wzu.edu.cn.
  • Li H; Institute of Theoretical and Computational Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China.
  • Zhang Z; Tangshan Key Laboratory of Optoelectronic Materials, School of Physics and Technology, Tang Shan Normal University, Tangshan 063000, China. zhencindy@pku.edu.cn.
  • Yang K; College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou 325035, China. xpyang@wzu.edu.cn.
  • Schipper D; The University of Texas at Austin, Department of Chemistry and Biochemistry, 1 University Station A5300, Austin, Texas, 78712, USA.
Dalton Trans ; 51(43): 16522-16526, 2022 Nov 08.
Article em En | MEDLINE | ID: mdl-36239711
ABSTRACT
A luminescent 56-metal Cd(II)-Sm(III) nanocluster (1, molecular sizes 4.5 × 2.7 × 2.7 nm) was constructed from a flexible Schiff base ligand, and its crystal structure was determined using the X-ray diffraction method. It shows a rapid triple-emissive response to 2,6-dichloro-4-nitroaniline (DCN, a common pesticide) with high sensitivity and selectivity, which can be used to quantitatively analyze the DCN concentrations in fruit extracts. The limits of detection (LODs) of 1 to DCN for the visible ligand-centered and Sm(III) emissions and NIR Sm(III) luminescence are from 0.95 µM to 2.81 µM.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Dalton Trans Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Dalton Trans Ano de publicação: 2022 Tipo de documento: Article