Your browser doesn't support javascript.
loading
Changes in heart rate variability of healthy subjects shortly exposed to printing shop particles and the effect of air purifier intervention.
Lyu, Lizhi; Xu, Yu; Wang, Hongbo; Guo, Xin; Gao, Yanjun; Duan, Shumin; Deng, Furong; Guo, Xinbiao; Wang, Yun.
Afiliação
  • Lyu L; Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, PR China.
  • Xu Y; Department of Respiratory Medicine, Beijing Jishuitan Hospital, Beijing, 100035, PR China.
  • Wang H; Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, PR China.
  • Guo X; Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, PR China.
  • Gao Y; Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, PR China.
  • Duan S; Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, PR China.
  • Deng F; Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, PR China.
  • Guo X; Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, PR China.
  • Wang Y; Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, PR China. Electronic address: wangyun@bjmu.edu.cn.
Environ Pollut ; 315: 120418, 2022 Dec 15.
Article em En | MEDLINE | ID: mdl-36257562
ABSTRACT
Particulate matter (PM) released by printers may cause airway inflammation and cardiac electrophysiological changes. We conducted a two-stage crossover study to examine the association between short-term exposure to printing shop particles (PSPs) and the heart rate variability (HRV) among healthy volunteers, as well as to evaluate the effect of air purifier intervention. The on-site assessments of PSPs and individual HRV parameters of the volunteers were used to analyze the influence of size-fractionated PSPs and air purifier intervention on HRV at different lag times after PSPs exposure (0 min, 5 min, 15 min, and 30 min) by using the linear mixed-effects models. We observed that changes in 6 HRV parameters were associated with particle mass concentration (PMC) of PSPs, and changes in 8 HRV parameters were associated with particle number concentration (PNC) of PSPs. The sensitive HRV parameters were the square root of the mean of the sum of the squares of differences between adjacent NN intervals (rMSSD), NN50 count divided by the total number of all NN intervals (pNN50), normalized high frequency power (nHF), very high frequency power (VHF), normalized low frequency power (nLF), and the ratio of low frequency power to high frequency power (LF/HF). Most HRV parameters exhibited the strongest effect associated with PMC and PNC at a lag time of 30 min. The air purifier intervention markedly reduced the PNC and PMC of size-fractionated PSPs, enhanced 5 HRV parameters, and decreased the nLF and LF/HF. Our study suggests that short-term exposure to PSPs can affect HRV parameters, reflecting changes in cardiac autonomic nervous activity, and the use of an air purifier can reduce the concentration of PSPs and improve the autonomic nervous system activity of the exposed individuals.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Filtros de Ar Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Environ Pollut Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Filtros de Ar Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Environ Pollut Ano de publicação: 2022 Tipo de documento: Article