Screen-printed sensors for efficient potentiometric analysis of tolperisone hydrochloride in presence of its co-formulated drugs.
Rizk, Mohamed; Hussein, Emad M; Toubar, Safaa; Ramzy, Emad; Helmy, Marwa I.
Afiliação
  • Rizk M; Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, EinHelwan, Cairo, 11795, Egypt.
  • Hussein EM; National Organization for Drug Control & Research (NODCAR), P.O. Box 29, Cairo, Egypt.
  • Toubar S; Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, EinHelwan, Cairo, 11795, Egypt.
  • Ramzy E; Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, EinHelwan, Cairo, 11795, Egypt.
  • Helmy MI; Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, EinHelwan, Cairo, 11795, Egypt. Marwa.ibrahim46@pharm.helwan.edu.eg.
BMC Chem ; 16(1): 89, 2022 Nov 07.
Article em En | MEDLINE | ID: mdl-36345022
Researchers seeking for green chemistry to help safeguard and boost the economy and the environment by discovering unique ways to decrease waste and find substitutes for dangerous chemicals. In this study, a green potentiometric ion-selective electrode (ISE) was developed for measurement of tolperisone HCl (TOLP) in bulk and Pharmaceutical dosage forms in presence of diclofenac sodium and paracetamol as co-formulated drugs. This paper presents the manufacture and characterization of a disposable potentiometric ion-selective strip with an enhanced detection limit for (TOLP) measurement in its tablet dosage form either alone or in presence of the co-formulated drugs. Numerous ion pairs (IPs), such as TOLP-tetraphenylborate (TOLP-TPB), TOLP-phosphotungstic acid (TOLP-PTA), and TOLP-ammonium Reinecke (TOLP- RKT) are tested in presence of different plasticizers. The optimal potentiometric response with a near Nernstian slope of 55.949 mV/decade was achieved within a linear concentration range of 5 [Formula: see text] 10-5 - 1 [Formula: see text] 10-2 M using (PTA) and ortho nitrophenyl octyl ether (o-NPOE) as a plasticizer. The effect of the nanoparticles on the membrane stability was studied using the graphene nanoplatelets which have an effective role in the enhancement of some constructed sensors stability. Finally, the developed technique is validated for the estimation of TOLP with high accuracy and precision.