Design and construction of a 9 MeV γ-ray source based on capture of moderated plutonium-beryllium neutrons in nickel.
Appl Radiat Isot
; 191: 110559, 2023 Jan.
Article
em En
| MEDLINE
| ID: mdl-36413938
We have designed and constructed a high-energy γ-ray source for detector characterisation and calibration. The source is a composite type based on a plutonium-beryllium neutron emitter embedded in a paraffin moderator, which is homogeneously mixed with nickel powder. The 9 MeV γ-ray source produces approximately 450 photons per second in 4π when 2.2×105 neutrons per second are emitted, corresponding to a surface flux of 9 MeV γ-rays of approximately 2.5×10-6 cm-2 per emitted neutron. Here we discuss the properties and design of this source, including the characterisation of homogeneity and high-energy γ-ray emission spectra.