Your browser doesn't support javascript.
loading
Biosensor based on bimetallic/graphene composite for non-enzymatic detection of hydrogen peroxide in living tumor cells.
Zhang, Qiyan; Guo, Lianshan; Li, Haoyu; Huang, Jianfeng; Li, Zhengzhao; Hong, Wenzhong; Wang, Jian; Bai, Zhihao; Zhu, Jianmeng.
Afiliação
  • Zhang Q; Blood Purification Centre, Chun'an First People's Hospital, Zhejiang Provincial People's Hospital Chun'an Branch, Hangzhou Medical College Affiliated Chun'an Hospital, Hangzhou, Zhejiang, P.R. China.
  • Guo L; Department of Emergency, The Second Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, P.R. China.
  • Li H; Department of Nephrology, The Second Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, P.R. China.
  • Huang J; Department of Nephrology, The Second Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, P.R. China.
  • Li Z; Department of Emergency, The Second Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, P.R. China.
  • Hong W; Clinical Laboratory, Chun'an First People's Hospital, Zhejiang Provincial People's Hospital Chun'an Branch, Hangzhou Medical College Affiliated Chun'an Hospital, Hangzhou, Zhejiang, P.R. China.
  • Wang J; Clinical Laboratory, Chun'an First People's Hospital, Zhejiang Provincial People's Hospital Chun'an Branch, Hangzhou Medical College Affiliated Chun'an Hospital, Hangzhou, Zhejiang, P.R. China.
  • Bai Z; College of Chemistry & Chemical Engineering, Guangxi University, Nanning, Guangxi, P.R. China.
  • Zhu J; Clinical Laboratory, Chun'an First People's Hospital, Zhejiang Provincial People's Hospital Chun'an Branch, Hangzhou Medical College Affiliated Chun'an Hospital, Hangzhou, Zhejiang, P.R. China.
Biotechnol Appl Biochem ; 70(3): 1024-1034, 2023 Jun.
Article em En | MEDLINE | ID: mdl-36427331
A highly sensitive electrochemical biosensor was manufactured with triple synergistic catalysis to detect hydrogen peroxide (H2 O2 ). In this study, a highly sensitive biosensor based on Prussian blue-chitosan/graphene-hemin nanomaterial/platinum and palladium nanoparticles (PB-CS/HGNs/Pt&Pd biosensor) was fabricated for the detection of H2 O2 . The materials described above were modified on the electrode surface and applied to catalyze the breakdown of hydrogen peroxide. The current response of the biosensor presented a linear relationship with H2 O2 concentration from 6 × 10-2 to 20 µM (R2 = 0.9766) and with the logarithm of H2 O2 concentration from 20 to 9×103  µM (R2 = 0.9782), the low detection limit of 25 nM was obtained at the signal/noise (S/N) ratio of 3. Besides, the biosensor showed an outstanding anti-interference ability and acceptable reproducibility. PB-CS/HGNs/Pt&Pd electrodes are effective in measuring H2 O2 from living tumor cells, which implies that the biosensor has the potential to assess reactive oxygen species in various living tumor cells.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biotechnol Appl Biochem Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biotechnol Appl Biochem Ano de publicação: 2023 Tipo de documento: Article