Your browser doesn't support javascript.
loading
Fluorescent Imprinted Nanoparticles for Sensing of Chlorogenic Acid in Coffee Extracts.
Gutiérrez-Ortiz, Anggy Lusanna; Vida, Veronica; Peterka, Matjaz; Tusar, Jasmina; Berti, Federico; Navarini, Luciano; Forzato, Cristina.
Afiliação
  • Gutiérrez-Ortiz AL; Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Trieste, Via Giorgieri 1, 34127 Trieste, Italy.
  • Vida V; Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Trieste, Via Giorgieri 1, 34127 Trieste, Italy.
  • Peterka M; COBIK, Mirce 21, 5270 Ajdovscina, Slovenia.
  • Tusar J; COBIK, Mirce 21, 5270 Ajdovscina, Slovenia.
  • Berti F; Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Trieste, Via Giorgieri 1, 34127 Trieste, Italy.
  • Navarini L; Illycaffè S.p.A., Via Flavia 110, 34147 Trieste, Italy.
  • Forzato C; Dipartimento di Scienze Chimiche e Farmaceutiche, Università degli Studi di Trieste, Via Giorgieri 1, 34127 Trieste, Italy.
Sensors (Basel) ; 22(24)2022 Dec 15.
Article em En | MEDLINE | ID: mdl-36560241
Green coffee beans are particularly rich in chlorogenic acids (CGAs), and their identification and quantification are usually performed by HPLC, coupled with mass spectrometry (LC-MS). Although there are a few examples of molecularly imprinted polymers (MIPs) for chlorogenic acid (5-CQA) recognition present in the literature, none of them are based on optical fluorescence, which is very interesting given its great sensitivity. In the present manuscript, fluorescent polymeric imprinted nanoparticles were synthetized following the non-covalent approach using hydrogenated 5-O-caffeoylquinic acid (H-5-CQA) as the template. The capability of the polymer to bind 5-CQA was evaluated by HPLC and fluorescence. A real sample of coffee extract was also analyzed to verify the selectivity of the polymer. Polymer fMIP01, containing 4-vinylpyridine and a naphtalimide derivative as monomers, showed a good response to the fluorescence quenching in the range 39 µM-80 mM. In the real sample, fMIP01 was able to selectively bind 5-CQA, while caffeine was not recognized. To demonstrate this, there is a promising system that can be exploited in the design of an optical sensor for 5-CQA detection. Polymer fMIP01 was immobilized by physical entrapment on a functionalized glass surface, showing a quenching of fluorescence with an increase of the CGA concentration between 156 µM and 40 mM.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Clorogênico / Nanopartículas Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Clorogênico / Nanopartículas Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article