Your browser doesn't support javascript.
loading
A novel electrochemical biosensing method with double-layered polymer brush modified electrode.
Inoue, Yuuki; Kim, Yeji; Hasegawa, Hijiri; Yoshida, Yasukazu; Sakakibara, Keita; Tsujii, Yoshinobu.
Afiliação
  • Inoue Y; LG Japan Lab Inc., LG Yokohama Innovation Center 7F, 1-2-13, Takashima, Nishi-ku, Yokohama-shi, Kanagawa 220-0011, Japan. Electronic address: yuuki.inoue@lgjlab.com.
  • Kim Y; LG Japan Lab Inc., LG Yokohama Innovation Center 7F, 1-2-13, Takashima, Nishi-ku, Yokohama-shi, Kanagawa 220-0011, Japan.
  • Hasegawa H; LG Japan Lab Inc., LG Yokohama Innovation Center 7F, 1-2-13, Takashima, Nishi-ku, Yokohama-shi, Kanagawa 220-0011, Japan.
  • Yoshida Y; LG Japan Lab Inc., LG Yokohama Innovation Center 7F, 1-2-13, Takashima, Nishi-ku, Yokohama-shi, Kanagawa 220-0011, Japan.
  • Sakakibara K; Institute for Chemical Research, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan.
  • Tsujii Y; Institute for Chemical Research, Kyoto University, Gokasho, Uji, Kyoto 611-0011, Japan. Electronic address: tsujii@scl.kyoto-u.ac.jp.
Colloids Surf B Biointerfaces ; 222: 113105, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36566689
ABSTRACT
We developed a novel electrochemical biosensor electrode that has a potential to reduce background noise for which we constructed an original conductive substrate modified with a double-layered polymer brush structure that is water impermeable and can control biomolecules adsorption/desorption. In this study, a hydrophobic poly(tert-butyl methacrylate) brush layer was prepared on a gold electrode, and then, the tert-butyl group near the outermost surface was dissociated by the acid treatment to obtain a hydrophilic carboxy group, thereby fabricating a conductive substrate with the double-layered polymer brush structure. Formation of the double-layered polymer brush structure was indicated by surface wettability and optical analyses. The potential difference and hydrogen ion concentration, which is a typical parameter of the surrounding environment, were linearly correlated with the gold electrode having a double-layered polymer brush structure with carboxyl groups. However, there was no correlation on gold electrodes with self-assembled monolayers presenting carboxy groups. It is considered that the pH responsiveness of the carboxy groups on the outermost surface could be exhibited remarkably because the charge state in the vicinity of the surface became constant due to the hydrophobic polymer brush layer having a certain thickness. The target DNA could be captured more efficiently at the probe DNA-immobilized electrode with the double-layered polymer brush structure than when using COOH-SAM. This is the first report of the application of the double-layered polymer brush structure for the electrochemical biosensing, and it will be an excellent surface modification method to reduce background noise.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Técnicas Biossensoriais Idioma: En Revista: Colloids Surf B Biointerfaces Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Técnicas Biossensoriais Idioma: En Revista: Colloids Surf B Biointerfaces Ano de publicação: 2023 Tipo de documento: Article