Modified moving average methodology applied to the treadmill stress testing analysis of microvolt T-wave alternans.
Pereira Filho, Horacio Gomes; Samesima, Nelson; Madaloso, Bruna Affonso; de Oliveira Tobias, Nancy Maria Martins; Facin, Mirella; Pastore, Carlos Alberto.
Afiliação
  • Pereira Filho HG; Instituto do Coracao (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Unidade de Eletrocardiografia, Sao Paulo, SP, 05403-900, Brazil.
  • Samesima N; Instituto do Coracao (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Unidade de Eletrocardiografia, Sao Paulo, SP, 05403-900, Brazil.
  • Madaloso BA; Instituto do Coracao (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Unidade de Eletrocardiografia, Sao Paulo, SP, 05403-900, Brazil.
  • de Oliveira Tobias NMM; Instituto do Coracao (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Unidade de Eletrocardiografia, Sao Paulo, SP, 05403-900, Brazil.
  • Facin M; Instituto do Coracao (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Unidade de Eletrocardiografia, Sao Paulo, SP, 05403-900, Brazil.
  • Pastore CA; Instituto do Coracao (InCor), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Unidade de Eletrocardiografia, Sao Paulo, SP, 05403-900, Brazil. ecg_pastore@incor.usp.br.
Sci Rep ; 12(1): 22454, 2022 12 27.
Article em En | MEDLINE | ID: mdl-36575194
ABSTRACT
Sudden cardiac death is impactful. There has been an increase in the search for tools capable of identifying individuals who are most susceptible, such as the microvolt T-wave alternans. This study aims to analyze the applicability of the modified moving average methodology to obtain the microvolt T-wave alternans using treadmill specific protocols. Medical records of patients during the period August 2006-December 2014 were retrospectively analyzed. Five hundred and thirty nine exams were then included, divided into groups according to the protocol and updating factor used Ellestad factor 8 or 32, Naughton factor 8 or 32. The topics for analysis were the alternans behavior, noise and confirmation according to the groups of leads analyzed (frontal, transversal and orthogonal planes). The greater microvolt T-wave alternans was found during the stress phase in most of the tests. Group Naughton 8 presented lower noise in this phase for the transverse and orthogonal planes (p = 0.0082 and p < 0.0001), with greater confirmation of frontal and orthogonal planes in comparison with group Ellestad 8 (p = 0.0002 and 0.0008). The results indicate the viability of simultaneous performance of the stress test and measurement of the T wave alternans with Naughton protocol with 1/8 updating factor.