Your browser doesn't support javascript.
loading
Three-dimensional soft tissue landmark detection with marching cube algorithm.
Lee, Yoonjung; Lee, Ji-Min; Park, Sun-Hyung; Choi, Yoon Jeong; Choi, Sung-Hwan; Hwang, Jae Joon; Yu, Hyung-Seog.
Afiliação
  • Lee Y; Department of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Lee JM; Department of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Park SH; Institute of Craniofacial Deformity, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Choi YJ; Department of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Choi SH; Institute of Craniofacial Deformity, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Hwang JJ; Department of Orthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Yu HS; Institute of Craniofacial Deformity, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
Sci Rep ; 13(1): 1544, 2023 01 27.
Article em En | MEDLINE | ID: mdl-36707701
ABSTRACT
Current method of analyzing three-dimensional soft tissue data, especially in the frontal view, is subjective and has poor reliability. To overcome this limitation, the present study aimed to introduce a new method of analyzing soft tissue data reconstructed by marching cube algorithm (Program S) and compare it with a commercially available program (Program A). Cone-beam computed tomography images of 42 patients were included. Two orthodontists digitized six landmarks (pronasale, columella, upper and lower lip, right and left cheek) twice using both programs in two-week intervals, and the reliability was compared. Furthermore, computer-calculated point (CC point) was developed to evaluate whether human error could be reduced. The results showed that the intra- and inter-examiner reliability of Program S (99.7-100% and 99.9-100%, respectively) were higher than that of Program A (64.0-99.9% and 76.1-99.9%, respectively). Moreover, the inter-examiner difference of coordinate values and distances for all six landmarks in Program S was lower than Program A. Lastly, CC point was provided as a consistent single point. Therefore, it was validated that this new methodology can increase the intra- and inter-examiner reliability of soft tissue landmark digitation and CC point can be used as a landmark to reduce human error.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article