Your browser doesn't support javascript.
loading
Technical tips and clinical experience with the Terumo Relay®Branch aortic endovascular graft.
Holzem, Katherine M; Sanchez, Luis A.
Afiliação
  • Holzem KM; Washington University School of Medicine, Section of Vascular Surgery, Department of Surgery, St. Louis, MO, USA - kmholzem@wustl.edu.
  • Sanchez LA; Washington University School of Medicine, Section of Vascular Surgery, Department of Surgery, St. Louis, MO, USA.
J Cardiovasc Surg (Torino) ; 64(1): 26-32, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36763069
ABSTRACT
Advances in thoracic endovascular aortic repair (TEVAR) are enabling the treatment of increasingly proximal pathology. While the practice of vascular surgery has thus far been mostly limited to TEVAR in zone 2 or more distally, there are emerging devices for zone 1 and zone 0 repair that do not require any further arch debranching compared with a zone 2 repair. Moreover, such devices set forth repair options for patients unable to tolerate the insult of open surgery. One zone 0 device under evaluation is the Terumo Relay®Branch (Terumo, Tokyo, Japan) endovascular graft, which is an off-the-shelf device based on the Relay®Pro platform (Terumo). This double branch device uniquely features a large gate, facilitating easy cannulation that contains two locking portal stents for the innominate artery (IA) and left common carotid artery (LCCA) branch grafts. Within our institution, we have had excellent technical success with Relay®Branch (Terumo) device deployments as part of the Early Feasibility Study, and other centers outside of the USA have published results with this device in small patient series. Notably, there is still a concerning stroke rate associated with the Relay®Branch (Terumo) device, with permanent stroke rates higher than expected but similar to those for open repair. Thus, these interventions must be undertaken with careful patient selection, thorough planning, and with the guidance of a proficient endovascular aortic team. In this article, we will outline the necessary preoperative workup, highlight device features, and detail the operative strategy, with tips for technical success. These guidelines from our experience will help facilitate successful utilization of this device when it becomes widely available in practice.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma da Aorta Torácica / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Guideline / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Cardiovasc Surg (Torino) Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma da Aorta Torácica / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Guideline / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Cardiovasc Surg (Torino) Ano de publicação: 2023 Tipo de documento: Article