High Dynamic Range Dual-Modal White Light Imaging Improves the Accuracy of Tumor Bed Sampling After Neoadjuvant Therapy for Breast Cancer.
Zhang, Meng; Liao, Jun; Jia, Zhanli; Qin, Chenchen; Zhang, Lingling; Wang, Han; Liu, Yao; Jiang, Cheng; Han, Mengxue; Li, Jinze; Wang, Kun; Wang, Xinran; Bu, Hong; Yao, Jianhua; Liu, Yueping.
Afiliação
  • Zhang M; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
  • Liao J; AI Lab, Tencent, Shenzhen, China.
  • Jia Z; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
  • Qin C; AI Lab, Tencent, Shenzhen, China.
  • Zhang L; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
  • Wang H; AI Lab, Tencent, Shenzhen, China.
  • Liu Y; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
  • Jiang C; AI Lab, Tencent, Shenzhen, China.
  • Han M; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
  • Li J; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
  • Wang K; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
  • Wang X; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
  • Bu H; Department of Pathology, West China Hospital, Sichuan University, Chengdu, China.
  • Yao J; AI Lab, Tencent, Shenzhen, China.
  • Liu Y; Department of Pathology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China.
Am J Clin Pathol ; 159(3): 293-303, 2023 03 13.
Article em En | MEDLINE | ID: mdl-36799717
OBJECTIVES: Accurate evaluation of residual cancer burden remains challenging because of the lack of appropriate techniques for tumor bed sampling. This study evaluated the application of a white light imaging system to help pathologists differentiate the components and location of tumor bed in specimens. METHODS: The high dynamic range dual-mode white light imaging (HDR-DWI) system was developed to capture antiglare reflection and multiexposure HDR transmission images. It was tested in 60 specimens of modified radical mastectomy after neoadjuvant therapy. We observed the differential transmittance among tumor tissue, fibrosis tissue, and adipose tissue. RESULTS: The sensitivity and specificity of HDR-DWI were compared with x-ray or visual examination to determine whether HDR-DWI was superior in identifying tumor beds. We found that tumor tissue had lower transmittance (0.12 ± 0.03) than fibers (0.15 ± 0.04) and fats (0.27 ± 0.07) (P < .01). CONCLUSIONS: HDR-DWI was more sensitive in identifying fiber and tumor tissues than cabinet x-ray and visual observation (P < .01). In addition, HDR-DWI could identify more fibrosis areas than the currently used whole slide imaging did in 12 samples (12/60). We have determined that HDR-DWI can provide more in-depth tumor bed information than x-ray and visual examination do, which will help prevent diagnostic errors in tumor bed sampling.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Patologia Clínica / Neoplasias da Mama / Diagnóstico por Imagem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Am J Clin Pathol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Patologia Clínica / Neoplasias da Mama / Diagnóstico por Imagem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Am J Clin Pathol Ano de publicação: 2023 Tipo de documento: Article