Your browser doesn't support javascript.
loading
Prospective intraindividual comparison of a standard 2D TSE MRI protocol for ankle imaging and a deep learning-based 2D TSE MRI protocol with a scan time reduction of 48.
Keller, Gabriel; Estler, Arne; Herrmann, Judith; Afat, Saif; Othman, Ahmed E; Nickel, Dominik; Koerzdoerfer, Gregor; Springer, Fabian.
Afiliação
  • Keller G; Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany. gabriel.keller@med.uni-tuebingen.de.
  • Estler A; Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany.
  • Herrmann J; Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany.
  • Afat S; Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany.
  • Othman AE; Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany.
  • Nickel D; Universitätsklink für Neuroradiologie, Johannes Gutenberg-Universität Mainz, Mainz, Germany.
  • Koerzdoerfer G; MR Applications Predevelopment, Siemens Healthcare GmbH, Allee Am Roethelheimpark 2, 91052, Erlangen, Germany.
  • Springer F; MR Applications Predevelopment, Siemens Healthcare GmbH, Allee Am Roethelheimpark 2, 91052, Erlangen, Germany.
Radiol Med ; 128(3): 347-356, 2023 Mar.
Article em En | MEDLINE | ID: mdl-36807027
PURPOSE: Magnetic resonance imaging (MRI) scan time remains a limited and valuable resource. This study evaluates the diagnostic performance of a deep learning (DL)-based accelerated TSE study protocol compared to a standard TSE study protocol in ankle MRI. MATERIAL AND METHODS: Between October 2020 and July 2021 forty-seven patients were enrolled in this study for an intraindividual comparison of a standard TSE study protocol and a DL TSE study protocol either on a 1.5 T or a 3 T scanner. Two radiologists evaluated the examinations regarding structural pathologies and image quality categories (5-point-Likert-scale; 1 = "non diagnostic", 5 = "excellent"). RESULTS: Both readers showed almost perfect/perfect agreement of DL TSE with standard TSE in all analyzed structural pathologies (0.81-1.00) with a median "good" or "excellent" rating (4-5/5) in all image quality categories in both 1.5 T and 3 T MRI. The reduction of total acquisition time of DL TSE compared to standard TSE was 49% in 1.5 T and 48% in 3 T MRI to a total acquisition time of 5 min 41 s and 5 min 46 s. CONCLUSION: In ankle MRI the new DL-based accelerated TSE study protocol delivers high agreement with standard TSE and high image quality, while reducing the acquisition time by 48%.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aprendizado Profundo / Tornozelo Tipo de estudo: Guideline / Observational_studies Limite: Humans Idioma: En Revista: Radiol Med Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aprendizado Profundo / Tornozelo Tipo de estudo: Guideline / Observational_studies Limite: Humans Idioma: En Revista: Radiol Med Ano de publicação: 2023 Tipo de documento: Article