Your browser doesn't support javascript.
loading
Bipolar Electrospray from Electrodeless Emitters for ESI without Electrochemical Reactions in the Sprayer.
Han, Zhongbao; Komori, Ryoki; Suzuki, Riku; Omata, Nozomu; Matsuda, Takeshi; Hishida, Shoki; Shuuhei, Takiguchi; Chen, Lee Chuin.
Afiliação
  • Han Z; Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.
  • Komori R; Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.
  • Suzuki R; Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.
  • Omata N; Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.
  • Matsuda T; Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.
  • Hishida S; Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.
  • Shuuhei T; Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.
  • Chen LC; Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan.
J Am Soc Mass Spectrom ; 34(4): 728-736, 2023 Apr 05.
Article em En | MEDLINE | ID: mdl-36815710
A bipolar ESI source is developed to generate a simultaneous emission of charged liquid jets of opposite polarity from an electrodeless sprayer. The sprayer consists of two emitters, and the electrosprays are initiated by applying a high potential difference (HV) across the counter electrodes facing each emitter. The sprayer and the liquid delivery system are made of all insulators without metal components, thus enabling the total elimination of electrochemical reactions taking place at the liquid-electrode interface in the typical electrosprayer. The bipolar electrospray has been implemented using an online configuration that uses a syringe pump for flow rate regulation and an offline configuration that relies on HV for adjusting the flow rate. The voltage-current and flow rate-current relationships of bipolar electrospray were found to be similar to the standard electrospray. The application of bipolar ESI to the mass spectrometry of protein, peptide, and metallocene without electrochemically induced oxidation/reduction is demonstrated.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Soc Mass Spectrom Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Soc Mass Spectrom Ano de publicação: 2023 Tipo de documento: Article